load test on three phase squirrel cage induction motor, predetermination of regulation using slip test, slip power recovery scheme slip ring induction motor, speed control of slip ring induction motor using chopper, brake test on 3 phase induction motor theory for experiment, slip ring induction motor general maintenance ppt, no load and blocked rotor test of three phase induction motory com,

AIM
To conduct load test on three-phase Slip Ring induction motor.
APPARATUS REQUIRED
PRECAUTION

The motor should be started without any load.
PROCEDURE
1. Connections are given as per the circuit diagram.
2. The TPST’S is closed and the motor is started using online starter to run at rated speed.
3. At no load the speed, current, voltage and power are noted down.
4. By applying the load gradually with the help of spring balance and brake drum arrangements.
5. The speed, current, voltage, po ....etc

[:=Read Full Message Here=:]
Title: LOAD TEST ON THREE PHASE ALTERNATOR
Page Link: LOAD TEST ON THREE PHASE ALTERNATOR -
Posted By: smart paper boy
Created at: Wednesday 10th of August 2011 12:44:57 PM
fislip test on alternator, load test on 3 phase alternator pdf, direct load test of an alternator pdf, characteristics of alternator on load, finding regulation of alternator by slip test, theory on slip test on salient pole alternator**isotropic diffusion, no load rotor test,

AIM
To conduct the load test on single phase alternator.
APPARATUS REQUIRED
PRECAUTION

1. The motor field rheostat should be kept in the minimum resistance position.
2. The alternator field potential divider should be in the minimum voltage position.
3. Initially all switches are in open position.
PROCEDURE
1. Note down the name plate details of motor and alternator
2. Connections are given as per circuit diagram.
3. The DPST is closed on supply side.
4. Using three point starter, the moto ....etc

[:=Read Full Message Here=:]
Title: REGULATION OF THREE-PHASE SALIENT POLE ALTERNATOR BY SLIP TEST
Page Link: REGULATION OF THREE-PHASE SALIENT POLE ALTERNATOR BY SLIP TEST -
Posted By: smart paper boy
Created at: Wednesday 10th of August 2011 12:44:37 PM
carmen electra pole, x pole, pole mounted substation pdf on project, regulation of alternator by emf and mmf method pdf, load test on 3 phase alternator circuit diagram, load test and graphs of three phase alternator, predetermination of three phase salient pole alternator by slip test,

AIM
To conduct the slip test on three phase alternator and predetermination the regulation through vector diagrams
APPARATUS REQUIRED
PRECAUTION
1. The Motor field Rheostat should be kept in minimum resistance position.
2. The Alternator field should be kept open throughout the experiment.
3. The direction of rotation due to prime mover and due to the Alternator run as the motor should be same.
4. Initially all the switches are kept open
PROCEDURE
1. The name plate details of the motor an ....etc

[:=Read Full Message Here=:]
Title: REGULATION OF 3PHASE ALTERNATOR BY EMF AND MMF METHODS
Page Link: REGULATION OF 3PHASE ALTERNATOR BY EMF AND MMF METHODS -
Posted By: smart paper boy
Created at: Friday 29th of July 2011 05:51:20 PM
advantages of pre determination of voltage regulation using zpf method over other various methods, regulation of three pahse alternator by emf and mmf method, regulation of 3 phase alternater by zpf method theory, difference between asa and mmf, mmf method voltage regulation procedure, difference between emf and mmf, scr of an alternator voltage regulation method of voltage regulation in ppt,

THEORY:
The regulation of a 3-phase alternator may be predetermined by conducting the Open Circuit (OC) and the Sort Circuit (SC) tests. The methods employed for determination of regulation are EMF or synchronous impedance method, MMF or Ampere Turns method and the ZPF or Potier triangle method. In this experiment, the EMF and MMF methods are used. The OC and SC graphs are plotted from the two tests. The synchronous impedance is found from the OC test. The regulation is then determined at different power factors by ....etc

[:=Read Full Message Here=:]
Title: SLIP TEST ON 3-PHASE ALTERNATOR
Page Link: SLIP TEST ON 3-PHASE ALTERNATOR -
Posted By: smart paper boy
Created at: Friday 29th of July 2011 05:51:52 PM
finding regulation of alternator by slip test, gpf slip mp 2012 13, muet result slip, gpf slip 2012 mp, ppt on limited slip differntial, slip guages advantages, slip test on salient pole alternator theory,

FUSE RATING:
(a)For Motor- 125% of rated current
= 125% of 17A=21.25A=25A
(b)For Alternator- 125% of rated current
=125% of 4A= 5A
THEORY:
In a salient pole alternator, the reactance of magnetic circuit along is along its quad stator axis. The alternator is driven by auxiliary prime mover at a speed slightly less than the synchronous speed under these conditions. The armature current is when the armature current mmf is in line with the field poles. The reactance by the magnetic field current is minim ....etc

[:=Read Full Message Here=:]
Title: circuit diagram for automatic active phase selector for single phase load from three phase supply
Page Link: circuit diagram for automatic active phase selector for single phase load from three phase supply -
Posted By:
Created at: Monday 10th of December 2012 02:04:55 AM
single phase watt hour meter ppt, kelebihan three phase system, phase change memory pdf malayalam, matlab simulink with three phase single pwm harmonics reduced, working principle single phase monitoring circuit pdf, wireless 3 phase motor starter, mutuval information on sensor selector,
i want the circuit diagram a automatic active phase selector for single phase load from three phase supply plase ....etc

[:=Read Full Message Here=:]
Title: REGULATION OF 3-PHASE ALTERNATOR BY POTIER AND ASA METHODS
Page Link: REGULATION OF 3-PHASE ALTERNATOR BY POTIER AND ASA METHODS -
Posted By: smart paper boy
Created at: Friday 29th of July 2011 05:51:34 PM
slip test and regulation, seminar on hydraulic pump and pressure regulation, theorey for regulation of an alternator by synchrons impedence method, voltage regulation of alternator by mmf method by graphical method, theory for regulation of regulation of alternator by emf and mmf method, pdf of detailed procedure of drawing the graph of emf method to find the voltage regulation of alternator, alternator working methods in hindi,

AIM:
To predetermine the regulation of three phase alternator by Potier and ASA methods and also to draw the vector diagrams.
FORMULAE USED:
Percentage regulation = Eo – Vrated x 100 (For both POTIER & ASA methods)
Vrated
PRECAUTION:
(i) The motor field rheostat should be kept in the minimum resistance position.
(ii) The Alternator field potential divider should be in the position of minimum potential.
(iii) Ini ....etc

[:=Read Full Message Here=:]
Title: pdf report of automatic active phase selector for single phase load from three phase supply
Page Link: pdf report of automatic active phase selector for single phase load from three phase supply -
Posted By:
Created at: Friday 21st of August 2015 11:44:43 AM
what is a phase report on a computer, me phase 1 project report model, active phase selector literature survey, pdf for automatic phase sequence selector system, ppt automatik phase changer pdf download, automatic active selector for single phase from three phase supply, three phase fault analysis project report,
Good pdf report for the electrical students because they have very useful this link ....etc

[:=Read Full Message Here=:]
Title: REGULATION OF THREE PHASE ALTERNATOR BY EMF MMF and ZPF
Page Link: REGULATION OF THREE PHASE ALTERNATOR BY EMF MMF and ZPF -
Posted By: smart paper boy
Created at: Wednesday 10th of August 2011 12:37:21 PM
regulation of three phase alternator, zpf method experiment theory, zpf emf and mmf method, determination of voltage regulation of alternator using zero power factor method, theory for regulation of alternator by synchronous impedance method mmf methods, mmf to emf conversion, regulation of three phase alternator by slip test pdf,

AIM
To conduct OC, SC and ZPF test on the three phase alternator and to predetermine the regulation of 3 phase alternator by EMF method, MMF method, & ZPF method also to verify by vector diagram.
APPARATUS REQUIRED
PRECAUTION

1. The motor field rheostat should be kept in the minimum resistance position.
2. The alternator field potential divider should be in the minimum voltage position.
3. Initially all switches are in open position.
PROCEDURE
A. OC.Test

1. Note down the name ....etc

[:=Read Full Message Here=:]
Title: project report on automatic active phase selector for single phase load from three phase supply
Page Link: project report on automatic active phase selector for single phase load from three phase supply -
Posted By:
Created at: Wednesday 16th of January 2013 04:37:16 PM
hindi pdf for single phase savmarsible**rt in ieee format, ppt on single phase rectifiers, how to make a single phase energy meter jammer, design and construction of a single phase automatic changeover switch with phase selector write up, advantages and disadvantages of phase sequence indicator, conversion of 3 phase to 5 phase, single phasing monitoring and prevention system for 3 phase industrial load ppt,
i m looking for the project report on automatic active phase selector for single phase load from three phase supply . help me for the same
????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????? ....etc

[:=Read Full Message Here=:]
Please report us any abuse/complaint to "omegawebs @ gmail.com"