AIM
To conduct the slip test on three phase alternator and predetermination the regulation through vector diagrams
APPARATUS REQUIRED
PRECAUTION
1. The Motor field Rheostat should be kept in minimum resistance position.
2. The Alternator field should be kept open throughout the experiment.
3. The direction of rotation due to prime mover and due to the Alternator run as the motor should be same.
4. Initially all the switches are kept open
PROCEDURE
1. The name plate details of the motor and alternator are noted.
2. Connections are made as per the circuit diagram.
3. Give the supply by closing the DPST Switch
4. Using the three point starter, start the motor to run at the synchronous speed by varying the motor field rheostat at the same time check whether the alternatorfield has been opened or not Apply 20% to 30% of the rated voltage to the armature of the alternator by adjusting the autotransformer.
5. To obtain the slip and the maximum oscillations of pointers, the speed is reduced slightly lesser than the synchronous speed.
6. Maximum current , minimum current , maximum voltage and minimum voltage are noted. The direct and quadrature axis resistances and reactances are calculated.
PROCEDURE TO DRAW THE VECTOR DIAGRAM:
1. Draw the line OA vector that represents the rated voltage v.
2. Draw the line OB vector to represents the rated current I, which makes an angle (it may lag/lead/in phase) with the voltage.
3. Draw the line AC vector to represent IRa drop which is parallel to OB vector.
4. Draw the perpendicular line CD vector to the line AC ( IRa drop )that represent IXq drop.
5. Draw the line from the origin through the point D, which consist the no load voltage (Eo).
6. Draw the pole axis through origin, which should be perpendicular to vector OD.
7. Draw the perpendicular line tom the pole axis from the same (point E) which should be passed through the point B[where, Vector OE represents direct access current (Id ) and vector EB represent quadrature axis current (Iq)].
8. Find out the reactive voltage drops XdId & Iq Xq.
9. Draw a parallel line (ie perpendicular to Id) to OD vector from the point C with the magnitude of the drop Id Xd (line CF).
10. Draw parallel line i.e. perpendicular to Iq to OE vector from F with the magnitude drop Iq,Xq(line FG).
11. Let the point at where the Iq,Xq drop meets OD line be G here the vector OG is represent the no load voltage(EO).
12. Find out voltage regulation by using the suitable formula.
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Tagged Pages: vector diagram representation of slip test, details on slip test of 3phase salient pole alternater, theory on slip test on salient pole alternator, slip test on salient pole alternator,
Popular Searches: slip test and regulation, regulation of three phase alternator, slip test on alternators, regulation of three pahse alternator by emf and mmf method, some salient features of linux os, pole mounted substation diagram, muet result slip,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  SINGLE PHASE INDUCTION MOTOR smart paper boy 1 4,115 13-11-2012, 11:59 AM
Last Post: seminar details
  THREE PHASE INDUCTION MOTOR smart paper boy 1 4,351 25-01-2012, 10:46 AM
Last Post: seminar addict
  server test Java source code smart paper boy 0 2,247 30-08-2011, 12:42 PM
Last Post: smart paper boy
  PROGRAM TO RECOGNIZE A STRING WITH THREE COSECUTIVE 0’s smart paper boy 0 1,653 10-08-2011, 11:44 AM
Last Post: smart paper boy
  Load Test on Three Phase Induction Motor (Squirrel gauge) smart paper boy 0 2,586 10-08-2011, 10:33 AM
Last Post: smart paper boy
  LOAD TEST ON SINGLE PHASE INDUCTION MOTOR smart paper boy 0 3,016 10-08-2011, 10:30 AM
Last Post: smart paper boy
  NO LOAD AND BLOCKED ROTOR TEST ON THREE PHASE SQUIRREL CAGE INDUCTION MOTOR smart paper boy 0 3,097 10-08-2011, 10:28 AM
Last Post: smart paper boy
  LOAD TEST ON THREE PHASE INDUCTION MOTOR (SLIP RING) smart paper boy 0 2,999 10-08-2011, 10:19 AM
Last Post: smart paper boy
  LOAD TEST ON THREE PHASE ALTERNATOR smart paper boy 0 2,133 10-08-2011, 10:14 AM
Last Post: smart paper boy
  REGULATION OF THREE PHASE ALTERNATOR BY EMF, MMF, and ZPF smart paper boy 0 4,791 10-08-2011, 10:07 AM
Last Post: smart paper boy

Forum Jump: