Title: INVESTIGATION OF ALTERNATORS SUBJECTED TO DIFFERENT LOADS AND MINIMIZATION OF ENCOUN
Page Link: INVESTIGATION OF ALTERNATORS SUBJECTED TO DIFFERENT LOADS AND MINIMIZATION OF ENCOUN -
Posted By: seminar class
Created at: Friday 11th of March 2011 06:40:20 PM
m b a s project report subjected to financial performance evaluation, ppt on parallel operation on alternators, different methods of technology, reid school of investigation, brushless alternators animations, how work distributed cycle minimization protocol, brushless alternators seminar,
presented by:
J.Chaithanya Bharathi
A.L.Harika
P.Divya Sree


Aim of the Project
To investigate the effects on the alternators when subjected to various types of loads and to minimize obtained harmonics
Overview
Project Objectives

 To determine various parameters under different loading conditions for:
• Laminated rotor alternator
• Solid rotor alternator
Parallel-connected alternators
 To analyze the voltage regulations under these conditions
 To analyze th ....etc

[:=Read Full Message Here=:]
Title: brushless alternators
Page Link: brushless alternators -
Posted By:
Created at: Thursday 10th of January 2013 11:15:23 AM
need of synchronization of alternators in hindi, regulation of salient pole alternators, brushless alternator ppt these alternators are 3f homo polar generators without any commutators slip rings and sliding contac, automatic voltage regulation of alternators, auto changeover panel in alternators pdf, advantages and disadvantages of emf and mmf methods in alternators, slip test on alternators,
....etc

[:=Read Full Message Here=:]
Title: crpf pay slip www crpf gov in pay slip your faithfully sainlee kom
Page Link: crpf pay slip www crpf gov in pay slip your faithfully sainlee kom -
Posted By:
Created at: Monday 24th of December 2012 11:04:34 PM
2013 pay slip, cms salary slip, ncr railway employe pay sleep, ghris pay slip november 2012, www ghrs pay slip, crpf pay slip ngo com, papers on slip formwork,
Show me december 2012 pay slip
jmjadjgtmeldajælgmatpmjmdajgptdwjgjad ....etc

[:=Read Full Message Here=:]
Title: LOAD TEST ON THREE PHASE INDUCTION MOTOR SLIP RING
Page Link: LOAD TEST ON THREE PHASE INDUCTION MOTOR SLIP RING -
Posted By: smart paper boy
Created at: Wednesday 10th of August 2011 12:49:33 PM
no load test on three phase induction motor, speed control of slip ring induction motor using chopper, blocked rotor test on 3 phase induction motor theory, ppt on no load test of induction motor, vector diagram representation of slip test, slip ring, regulation of three phase alternator by slip test pdf,

AIM
To conduct load test on three-phase Slip Ring induction motor.
APPARATUS REQUIRED
PRECAUTION

The motor should be started without any load.
PROCEDURE
1. Connections are given as per the circuit diagram.
2. The TPST’S is closed and the motor is started using online starter to run at rated speed.
3. At no load the speed, current, voltage and power are noted down.
4. By applying the load gradually with the help of spring balance and brake drum arrangements.
5. The speed, current, voltage, po ....etc

[:=Read Full Message Here=:]
Title: parallel operation of automotive alternators
Page Link: parallel operation of automotive alternators -
Posted By:
Created at: Friday 21st of August 2015 06:39:20 PM
regulation of salient pole alternators, parallel operation of alternators, ppt on parallel operation of alternators, methods of synchronization of alternators ppt, brushless alternators theory, ppt on parallel operation on alternators, advantages and disadvantage of alternators,
Can I connect two or more car alternators in parallel? Do I need to use a single external regulator?
Thank you,
Bela [email protected] ....etc

[:=Read Full Message Here=:]
Title: parallel operation of alternators ppt
Page Link: parallel operation of alternators ppt -
Posted By:
Created at: Monday 26th of November 2012 02:06:34 AM
brushless alternators ppt download, advantages and disadvantage of alternators, brushless alternators theory, parallel operation of alternators, brushless alternators abstract seminar, automatic voltage regulation of alternators, regulation of salient pole alternators,
please give me ppt file on this subject,sir ....etc

[:=Read Full Message Here=:]
Title: BRUSHLESS ALTERNATORS
Page Link: BRUSHLESS ALTERNATORS -
Posted By: seminar projects crazy
Created at: Friday 30th of January 2009 01:47:17 AM
detailes kel in thripunithura, brushless alternators and its working principle, brushless alternators ppt download, alternators voltage regulation by zpf method ppt, brushless alternators seminar topic, automatic voltage regulation of alternators, synchronous alternators,
The Kerala Electrical & Allied Engineering Co. Ltd., popularly known as KEL was established in 1964 in the State of Kerala, India and is fully owned by the State Government. As a company engaged in multifarious activities, it has gradually broadened its manufacturing base strategically to reach a wider domestic and overseas market. The company has four manufacturing units located in various districts of the State. They are Kundara Unit in Kollam district, Mamala Unit in Ernakulam district, Olavakkod Unit in Palakkad district and Kasargod Unit i ....etc

[:=Read Full Message Here=:]
Title: LOAD TEST ON 3-PHASE SLIP RING INDUCTION MOTOR
Page Link: LOAD TEST ON 3-PHASE SLIP RING INDUCTION MOTOR -
Posted By: smart paper boy
Created at: Friday 29th of July 2011 05:53:59 PM
why is the field kept open in slip test of alternator, blocked rotor test on 3 phase induction motor theory, no load and blocked rotor test on 3 phase induction motor pdf, slip test on alternators, employe salry slip ssipl, short ckt test on slip ring induction motor, cisfpay slip,

AIM :
To conduct a direct load test on a 3-phase slip ring induction motor and to draw the performance characteristics.
FUSE RATING-
FOR- STATOR- 125% 0f 7.5A = 10A
FOR ROTOR – 125% of 11A = 15A
THEORY:
Slip ring induction motor is also called as phase wound motor. The motor is wound for as many poles as the no. of stator poles and always wound 3-Ф even while the stator is wound two-phase. The other three windings are brought out and connected to three insulated slip-rings mounted on t ....etc

[:=Read Full Message Here=:]
Title: REGULATION OF THREE-PHASE SALIENT POLE ALTERNATOR BY SLIP TEST
Page Link: REGULATION OF THREE-PHASE SALIENT POLE ALTERNATOR BY SLIP TEST -
Posted By: smart paper boy
Created at: Wednesday 10th of August 2011 12:44:37 PM
a pole monted substation seminar abstract report, automatic voltage regulation of an alternator used in ukai, automatic voltage regulation of alternator used in ukai pp, circuit for slip test on salient pole alternator, shaded pole motor ppt, regulation of salient pole alternator pdf, regulation of three phase alternator,

AIM
To conduct the slip test on three phase alternator and predetermination the regulation through vector diagrams
APPARATUS REQUIRED
PRECAUTION
1. The Motor field Rheostat should be kept in minimum resistance position.
2. The Alternator field should be kept open throughout the experiment.
3. The direction of rotation due to prime mover and due to the Alternator run as the motor should be same.
4. Initially all the switches are kept open
PROCEDURE
1. The name plate details of the motor an ....etc

[:=Read Full Message Here=:]
Title: SLIP TEST ON 3-PHASE ALTERNATOR
Page Link: SLIP TEST ON 3-PHASE ALTERNATOR -
Posted By: smart paper boy
Created at: Friday 29th of July 2011 05:51:52 PM
vector diagram representation of slip test, slip test on salient pole alternator theory, reason behind the name of slip test on salient pole alternator, www comcrpfpay slip, www crpfpay, employe salry slip ssipl, www nwr epay slip in,

FUSE RATING:
(a)For Motor- 125% of rated current
= 125% of 17A=21.25A=25A
(b)For Alternator- 125% of rated current
=125% of 4A= 5A
THEORY:
In a salient pole alternator, the reactance of magnetic circuit along is along its quad stator axis. The alternator is driven by auxiliary prime mover at a speed slightly less than the synchronous speed under these conditions. The armature current is when the armature current mmf is in line with the field poles. The reactance by the magnetic field current is minim ....etc

[:=Read Full Message Here=:]