REGULATION OF 3–PHASE ALTERNATOR BY EMF AND MMF METHODS
#1

[attachment=14897]
THEORY:
The regulation of a 3-phase alternator may be predetermined by conducting the Open Circuit (OC) and the Sort Circuit (SC) tests. The methods employed for determination of regulation are EMF or synchronous impedance method, MMF or Ampere Turns method and the ZPF or Potier triangle method. In this experiment, the EMF and MMF methods are used. The OC and SC graphs are plotted from the two tests. The synchronous impedance is found from the OC test. The regulation is then determined at different power factors by calculations using vector diagrams. The EMF method is also called pessimistic method as the value of regulation obtained is much more than the actual value. The MMF method is also called optimistic method as the value of regulation obtained is much less than the actual value. In the MMF method the armature leakage reactance is treated as an additional armature reaction. In both methods the OC and SC test data are utilized.
PRECAUTIONS:
(i) The motor field rheostat should be kept in the minimum resistance position.
(ii) The alternator field potential divider should be kept in the minimum voltage position.
(iii) Initially all switches are in open position.
PROCEDURE: (FOR BOTH EMF AND MMF METHODS)
1. Note down the name plate details of the motor and alternator.
2. Connections are made as per the circuit diagram.
3. Switch ON the supply by closing the DPST switch.
4. Using the Three point starter, start the motor to run at the synchronous speed by adjusting the motor field rheostat.
5. Conduct Open Circuit test by varying the potential divider for various values of field current and tabulate the corresponding Open Circuit Voltage readings.
6. Conduct Short Circuit test by closing the TPST switch and adjust the potential divider to set the rated armature current and tabulate the corresponding field current.
7. The Stator resistance per phase is determined by connecting any one phase stator winding of the alternator as per the circuit diagram using MC voltmeter and ammeter of suitable ranges.
PROCEDURE TO DRAW GRAPH FOR EMF METHOD:
1. Draw the Open Circuit Characteristic curve (Generated Voltage per phase VS Field current).
2. Draw the Short Circuit Characteristics curve (Short circuit current VS Field current)
3. From the graph find the open circuit voltage per phase (E1 (ph) for the rated short circuit current (Isc).
4. By using respective formulae find the Zs, Xs, Eo and percentage regulation.
PROCEDURE TO DRAW GRAPH FOR MMF METHOD:
1. Draw the Open Circuit Characteristic curve (Generated Voltage per phase VS Field current).
2. Draw the Short Circuit Characteristics curve (Short circuit current VS Field current)
3. Draw the line OL to represent
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Popular Searches: ppt on emf and mmf method, automatic voltage regulation of alternator used in ukai ppt, voltage regulation of alternator by zpf method theory, emf survey procedure in telecom, advantages and disadvantages of emf method of alternator, formulas of emf mmf, mmf and emf method,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  SINGLE PHASE INDUCTION MOTOR smart paper boy 1 4,115 13-11-2012, 11:59 AM
Last Post: seminar details
  THREE PHASE INDUCTION MOTOR smart paper boy 1 4,351 25-01-2012, 10:46 AM
Last Post: seminar addict
  Load Test on Three Phase Induction Motor (Squirrel gauge) smart paper boy 0 2,585 10-08-2011, 10:33 AM
Last Post: smart paper boy
  LOAD TEST ON SINGLE PHASE INDUCTION MOTOR smart paper boy 0 3,016 10-08-2011, 10:30 AM
Last Post: smart paper boy
  NO LOAD AND BLOCKED ROTOR TEST ON THREE PHASE SQUIRREL CAGE INDUCTION MOTOR smart paper boy 0 3,096 10-08-2011, 10:28 AM
Last Post: smart paper boy
  LOAD TEST ON THREE PHASE INDUCTION MOTOR (SLIP RING) smart paper boy 0 2,999 10-08-2011, 10:19 AM
Last Post: smart paper boy
  LOAD TEST ON THREE PHASE ALTERNATOR smart paper boy 0 2,133 10-08-2011, 10:14 AM
Last Post: smart paper boy
  REGULATION OF THREE-PHASE SALIENT POLE ALTERNATOR BY SLIP TEST smart paper boy 0 3,528 10-08-2011, 10:14 AM
Last Post: smart paper boy
  REGULATION OF THREE PHASE ALTERNATOR BY EMF, MMF, and ZPF smart paper boy 0 4,790 10-08-2011, 10:07 AM
Last Post: smart paper boy
  ALTERNATOR (BRUSHLESS TYPE) smart paper boy 0 1,531 02-08-2011, 04:51 PM
Last Post: smart paper boy

Forum Jump: