Important..!About asa method procedure for regulation of alternator is Not Asked Yet ? .. Please ASK FOR asa method procedure for regulation of alternator BY CLICK HERE ....Our Team/forum members are ready to help you in free of cost...
Below is stripped version of available tagged cloud pages from web pages.....
Thank you...
Thread / Post Tags
Title: procedure related to 3 phase alternator by synchronous impedance method
Page Link: procedure related to 3 phase alternator by synchronous impedance method -
Posted By:
Created at: Friday 02nd of November 2012 12:37:00 AM
procedure to the method without using graph..............etc

[:=Read Full Message Here=:]
Title: The Global Voltage Regulation
Page Link: The Global Voltage Regulation -
Posted By: computer science crazy
Created at: Sunday 21st of September 2008 12:18:02 PM
Based on closed form expressions for the power frequency voltages and currents in a typical distribution network, the voltage regulation VR at any time point during the day could be evaluated. It will depend primarily on the network configuration, the daily load curve, the load density and its power factor as well as level of the reactive power compensation.

The computed at a certain time?t? can give a useful indicator for the voltage constancy over the network at that time point. The concept of ?Global Voltage Regulation? is introduced. Th..............etc

[:=Read Full Message Here=:]
Title: Automatic voltage regulation of alternator used in UKAI PP
Page Link: Automatic voltage regulation of alternator used in UKAI PP -
Posted By: chodekiran
Created at: Friday 05th of March 2010 12:53:47 PM
. Automatic voltage regulation of alternator used in UKAI PP..............etc

[:=Read Full Message Here=:]
Title: REGULATION OF THREE PHASE ALTERNATOR BY EMF MMF and ZPF
Page Link: REGULATION OF THREE PHASE ALTERNATOR BY EMF MMF and ZPF -
Posted By: smart paper boy
Created at: Wednesday 10th of August 2011 12:37:21 PM
presentation slides on regulation of 3 phase alternator by emf method only, difference mmf zpf emf, regulation of 3 phase alternator using emf method, yhsm inucbr 001, regulation of three phase alternator by emf and mmf,

AIM
To conduct OC, SC and ZPF test on the three phase alternator and to predetermine the regulation of 3 phase alternator by EMF method, MMF method, & ZPF method also to verify by vector diagram.
APPARATUS REQUIRED
PRECAUTION

1. The motor field rheostat should be kept in the minimum resistance position.
2. The alternator field potential divider should be in the minimum voltage position.
3. Initially all switches are in open position.
PROCEDURE
A. OC.Test

1. Note down the name..............etc

[:=Read Full Message Here=:]
Title: REGULATION OF 3PHASE ALTERNATOR BY EMF AND MMF METHODS
Page Link: REGULATION OF 3PHASE ALTERNATOR BY EMF AND MMF METHODS -
Posted By: smart paper boy
Created at: Friday 29th of July 2011 05:51:20 PM

THEORY:
The regulation of a 3-phase alternator may be predetermined by conducting the Open Circuit (OC) and the Sort Circuit (SC) tests. The methods employed for determination of regulation are EMF or synchronous impedance method, MMF or Ampere Turns method and the ZPF or Potier triangle method. In this experiment, the EMF and MMF methods are used. The OC and SC graphs are plotted from the two tests. The synchronous impedance is found from the OC test. The regulation is then determined at different power factors by ..............etc

[:=Read Full Message Here=:]
Title: REGULATION OF 3-PHASE ALTERNATOR BY POTIER AND ASA METHODS
Page Link: REGULATION OF 3-PHASE ALTERNATOR BY POTIER AND ASA METHODS -
Posted By: smart paper boy
Created at: Friday 29th of July 2011 05:51:34 PM
asa method procedure for regulation of alternator,

AIM:
To predetermine the regulation of three phase alternator by Potier and ASA methods and also to draw the vector diagrams.
FORMULAE USED:
Percentage regulation = Eo – Vrated x 100 (For both POTIER & ASA methods)
Vrated
PRECAUTION:
(i) The motor field rheostat should be kept in the minimum resistance position.
(ii) The Alternator field potential divider should be in the position of minimum potential.
(iii) Ini..............etc

[:=Read Full Message Here=:]
Title: Automatic voltage regulation of alternator used in UKAI PP
Page Link: Automatic voltage regulation of alternator used in UKAI PP -
Posted By: chodekiran
Created at: Friday 05th of March 2010 12:56:28 PM
related information of Automatic voltage regulation of alternator..............etc

[:=Read Full Message Here=:]
Title: A New Induction Motor Vf Control Method Capable of High-Performance Regulation
Page Link: A New Induction Motor Vf Control Method Capable of High-Performance Regulation -
Posted By: smart paper boy
Created at: Wednesday 22nd of June 2011 07:04:12 PM
A New Induction Motor V/f Control Method Capable of High-Performance Regulation at Low Speeds
Abstract
A novel open-loop speed control method for induction motors that provides high output torque and nearly zero steady-state speed error at any frequency is presented. The control scheme is based on the popular constant volts per hertz (V/f) method using low-cost open-loop current sensors. Only stator current measurements are needed to compensate for both stator resistance drop and slip frequency. The scheme proposed fully compen..............etc

[:=Read Full Message Here=:]
Title: REGULATION OF THREE-PHASE SALIENT POLE ALTERNATOR BY SLIP TEST
Page Link: REGULATION OF THREE-PHASE SALIENT POLE ALTERNATOR BY SLIP TEST -
Posted By: smart paper boy
Created at: Wednesday 10th of August 2011 12:44:37 PM
slip test on salient pole alternator, vector diagram representation of slip test, theory on slip test on salient pole alternator, details on slip test of 3phase salient pole alternater,

AIM
To conduct the slip test on three phase alternator and predetermination the regulation through vector diagrams
APPARATUS REQUIRED
PRECAUTION
1. The Motor field Rheostat should be kept in minimum resistance position.
2. The Alternator field should be kept open throughout the experiment.
3. The direction of rotation due to prime mover and due to the Alternator run as the motor should be same.
4. Initially all the switches are kept open
PROCEDURE
1. The name plate details of the motor an..............etc

[:=Read Full Message Here=:]
Title: Expression and Regulation of Protein Complexes in Yeast
Page Link: Expression and Regulation of Protein Complexes in Yeast -
Posted By: Computer Science Clay
Created at: Sunday 01st of March 2009 01:12:44 PM
Expression and Regulation of Protein Complexes in Yeast

Structural Biology and Centre for Computational Biology, Hospital for Sick Children, 555 University Avenue, Toronto, M5G 1X8, Canada 2 Service de Conformation de Macromolecules Biologiques, Centre de Biologie Structurale et Bioinformatique, Université Libre de Bruxelles, CP263, Blvd. du Triomphe, 1050, Bruxelles, Belgium Multiprotein complexes play an essential role in many cellular processes.

But our knowledge of the mecha..............etc

[:=Read Full Message Here=:]