AUTOMATIC METER READING USING WIRELESS NETWORKS
#1

[attachment=14307]
Highly Person dependant.
Human errors cannot be avoided.
Energy Audits performed based on bill collection which is highly inaccurate.
Billing done mainly on estimated/ monthly average basis
Inability to monitor and control discrete loads
Billing cycle requires excessive time.
Meter data used only for billing, cannot help in analysis like demand analysis, energy audit, pinpointing losses, etc.
ABSTRACT
Automatic meter reading is needed to provide benefits to customer,
utilities and government and Automatic meter reading advantage include
Real time pricing
Automated billing
Remote connect / disconnect
Reducing peak demand for energy
EXISTING METHOD
Power line communication
Message over GSM network
Telephone lines
Radio frequency (blue tooth, WI-FI, Zigbee)
1.Power line communication
Advantage:
support large network Cabling is already available
Disadvantage:
limited band width
Noisy medium, high signal attenuation
Susceptibility to interference from near by device
2. Message over GSM network
3. Telephone lines
Advantage:
highly reliable, inexpensive
Disadvantage:
More telephone lines required
4. Radio frequency (blue tooth, WI-FI, Zigbee)
Advantage:
Highly reliable, inexpensive
Disadvantage:
Security problem
METER DATA USING WIRELESS NETWORKS
To develop a means of translating readings from meter dials into digital form, to send digital metering data from the customer site to a central point without data failure.
The digital metering data is available at the power station (Main Server) at all times, based on the data available billing, customer consumption , consumption pattern and various security measures etc can be carried out with data available.
METER DATA USING WIRELESS NETWORKS
Thousands of nodes (measuring device) forms a Pico network, data are fused and delivered to Sub server (Sub station) then transferred to centralized location (Main Server). 
A suitable protocol is used that suits for AMR.
End to end connection require addressing every node and results in high end to end delay instead we go for hop by hop reliability .
Reliability is achieved using heterogeneous node as cluster head instead of homogeneous node
METER DATA USING WIRELESS NETWORKS
Traffic load is reduced by means of data aggregation.
Fault detection protocol to find node failures.
AMR technical requirements reliability, scalability, real time communication, security.
Data collection through – fixed scheduling, event-driven, demand- driven
Reply
#2

to get information about the topic AUTOMATIC METER READING SYSTEM full report ,ppt and related topic refer the page link bellow
http://studentbank.in/report-automatic-m...ing-system

http://studentbank.in/report-automatic-m...?pid=65663

http://studentbank.in/report-automatic-p...sm-network

http://studentbank.in/report-modeling-an...-power-lin

http://studentbank.in/report-automatic-m...amr?page=2

http://studentbank.in/report-gsm-based-a...er-reading

http://studentbank.in/report-automatic-m...5#pid44485

http://studentbank.in/report-automatic-m...eading-amr

http://studentbank.in/report-automatic-m...amr?page=3

http://studentbank.in/report-automatic-m...s-networks
Reply
#3



to get information about the topic "automatic meter reading using rf technology" full report ppt and related topic refer the page link bellow

http://studentbank.in/report-automatic-m...e=threaded

http://studentbank.in/report-automatic-m...amr?page=3

http://studentbank.in/report-automatic-m...e=threaded

http://studentbank.in/report-automatic-m...e=threaded
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Popular Searches: automatic meter reading water ppttection, automatic meter reading project report, ppt on automatic meter reading using power line communication, automatic meter reading ppt, automatic meter reading water ppt, ppt on wireless energy meter reading using rf technology, automatic meter reading india,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  Automatic Phase Selector (APS) computer science topics 7 15,687 19-07-2017, 09:00 PM
Last Post: Guest
  Military combat robot wireless controlled. Camera helps keeping an eye on border. seminar class 6 11,412 09-06-2017, 10:27 AM
Last Post: jaseela123d
  AUTOMATIC STREET LIGHT CONTROL WITH SENSOR TECHNOLOGY seminar class 2 11,770 22-05-2017, 11:07 AM
Last Post: yasminoth93
  WORMHOLE ATTACK DETECTION IN WIRELESS ADHOC SENSOR NETWORKS seminar class 7 19,110 17-08-2016, 09:23 AM
Last Post: jaseela123d
  AUTOMATIC BUS STATION ANNOUNCEMENT SYSTEM full report project report tiger 4 10,931 13-08-2016, 11:16 AM
Last Post: jaseela123d
  Wireless Communication – ZigBee / Bluetooth / RF / IR based major projects for ECE project topics 9 19,325 16-07-2016, 03:45 PM
Last Post: jaseela123d
  HIGHWAY SPEED SENSING AND AUTOMATIC BREAKING SYSTEM smart paper boy 7 13,795 16-03-2016, 03:02 PM
Last Post: dhanabhagya
  AUTOMATIC STREET LIGHT CONTROL-EMBEDDED BASED PROJECT project topics 18 30,444 11-02-2016, 02:03 PM
Last Post: seminar report asees
  Wireless based Automatic dam water level control shutter open /closed with emergency smart paper boy 4 11,478 11-09-2015, 02:00 PM
Last Post: seminar report asees
  MICROCONTROLLER BASED AUTOMATIC RAILWAY GATE CONTROL full report project topics 49 58,041 10-09-2015, 03:18 PM
Last Post: seminar report asees

Forum Jump: