liquid level Alarm
#1

[attachment=1133]
liquid level Alarm
Here is a simple circuit for Liquid level alarm. It is built Around two BC547 transistors(T1 and T2) and two timer 555 ICs (IC1and IC2). Both IC1 and IC2 are wired in astable multivibrator mode. TimerIC1 produces low frequency, while timer IC2 produces high frequency. As a result, a beeping tone is generated when the liquid tank is full. Initially, when the tank is empty, transistor T1 does not conduct. Consequently, transistor T2 conducts and pin 4 of IC1 is low. This low voltage disables IC1 and it does not oscillate. The low output of IC1 disables IC2and it does not oscillate. As a result, no sound is heard from the speaker. But when the tank gets filled up, transistor T1 conducts. Consequently, transistor T2 is cut off and pin 4 ofIC1 becomes high. This high voltage enables IC1 and it oscillates to produce low frequencies at pin 3. This low-frequency output enables IC2 and it also oscillates to produce high frequencies. As a result, sound is produced from the speaker. Using preset VR1 you can control the volume of the sound from the speaker. The circuit can be powered from a9V battery or from mains by using a 9Vpower adaptor. Assemble the circuit on a general purpose PCB and enclose in a suitable cabinet. Install two water-level probes using metal strips such that one touches the bottom of the tank and the other touches the maximum level of the water in the tank. Interconnect the sensor and the circuit using a flexible wire.
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Popular Searches: essay liquid level alarm project report, sms alarm, level 1, liquid level alarm project report, buglar alarm, project for liquid level alarm, liquid engineering pdf**for online jewellery shopping project,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  Wireless based Automatic dam water level control shutter open /closed with emergency smart paper boy 4 11,330 11-09-2015, 02:00 PM
Last Post: seminar report asees
  AUTOMATIC WATER LEVEL MONITORING SYSTEM computer science crazy 3 4,835 23-10-2014, 11:47 PM
Last Post: jaseela123d
  Multi Level Car Parking System a presentation mechanical wiki 13 25,059 22-06-2014, 05:58 PM
Last Post: Guest
  Level Control in Horizontal Tank by Fuzzy-PID Cascade Controller smart paper boy 1 1,551 26-11-2012, 12:57 PM
Last Post: seminar details
  Radio Frequency based Real time Child monitoring and alarm system smart paper boy 1 2,479 26-11-2012, 12:55 PM
Last Post: seminar details
  PIR BASED AUTO DIALER SECURITY and SAFETY ALARM seminar presentation 3 4,629 21-11-2012, 11:41 AM
Last Post: seminar details
  Automated alarm CirCuits mechanical wiki 2 3,334 17-11-2012, 12:15 PM
Last Post: seminar details
  Digital Clock with Alarm project topics 2 3,065 15-11-2012, 11:32 AM
Last Post: seminar details
  Boiler Water Level Control System seminar presentation 3 5,821 20-02-2012, 04:18 PM
Last Post: seminar paper
  AUTOMATIC WATER LEVEL MONITORING & CONTROLLER USING MICROCONTROLLER CIRCUIT seminar class 1 7,185 20-02-2012, 04:17 PM
Last Post: seminar paper

Forum Jump: