A Modular Single-Phase Power-Factor-Correction Scheme With a Harmonic Filtering
#1

A Modular Single-Phase Power-Factor-Correction Scheme With a Harmonic Filtering Function



.pdf   A Modular Single-Phase Power-Factor-Correction.pdf (Size: 708.62 KB / Downloads: 10)

INTRODUCTION

THE recent developments in power electronics technology
enable us to introduce power converters into
telecommunication applications to drive various loads in
single-phase power distribution systems. The expanding use
of electric loads controlled by power electronics has made
power converters an important and unquestionable part of the
modern society. Power supply systems in telecommunication
applications employ several parallel-connected ac-to-dc and
dc-to-dc power converters. Such a system offers modularity,
redundancy, and is easily scalable to higher power levels.
Such parallel-connected systems normally consist of several
single-phase power-factor-correction (PFC) stages connected
to the same input utility as shown in Fig. 1 [1]–[3]. Therefore,
the system cannot accomplish low-cost power supply and its
control could be complicated.


PROPOSED TOPOLOGY

The typical converter system in telecommunication applications
has several PFC circuits in parallel as shown in Fig. 1.
Such a system can be replaced by either dc-link shared or independent
modular scheme which consists of several ac-to-dc
and dc-to-dc power converters employing only one PFC circuit
and several NLs. Fig. 2 shows the possible combination with
isolated converter. Each scheme is capable of achieving unity
power factor with sinusoidal current waveform by injecting harmonic
current through a PFC circuit [6], [7]. Fig. 3 shows the
proposed telecommunication PFC-BC paralleled with nonlinear
loads and its waveforms.


CONTROLLER DESIGN

The control block diagram for the PFC boost converter is
shown in Fig. 5 with and without current reference generator.
Fig. 5(a) introduces the principle for the harmonic compensation
and Fig. 5(b) shows a simple control block diagram which
can be easily implemented by analog circuits. The control block
diagram consists of a dc-voltage proportional-plus-integral (PI)
controller, current controller, harmonic reference current generator,
and the disturbance. The rectified voltage can be considered
as a disturbance since the input voltage of the boost converter
is basically a dc quantity.


CONCLUSIONS
A modular single-phase PFC with a harmonic filtering function
has been presented. It has been shown that a single-phase
PFC scheme can be suitably altered to achieve harmonic filtering
function of nonlinear loads connected to the system.
proposed approach should result in lower cost. Experimental results
from a laboratory prototype system validate the PFC capability.
Reply
#2
i need full theorey of a modular single phase power factor correction scheme with a harmonic filtering function, power factor correction pdf,
Reply
#3

To get full information or details of A Modular Single-Phase Power-Factor-Correction Scheme With a Harmonic Filtering please have a look on the pages

http://studentbank.in/report-a-modular-s...-filtering

http://studentbank.in/report-a-single-ph...-converter

if you again feel trouble on A Modular Single-Phase Power-Factor-Correction Scheme With a Harmonic Filtering please reply in that page and ask specific fields
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Popular Searches: a new single phase soft switching power factor correction converter, dynamic en route filtering scheme source code, harmonic power filter pdf 2014, slip power recovery scheme download, seminar full report of single phase soft swithing power factor correction converter, single phase soft switching power factor correction converter ppt, windows xp presentation power scheme,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  SCADA FOR POWER SYSTEM AUTOMATION seminar paper 3 4,829 05-04-2016, 01:07 PM
Last Post: dhanabhagya
  AUTOMATIC PHASE CHANGER full report seminar paper 3 3,547 27-03-2015, 10:06 AM
Last Post: seminar report asees
  Advanced Construction Methods for New Nuclear Power Plants seminar details 3 3,115 24-10-2014, 11:40 PM
Last Post: jaseela123d
  SURATGARH SUPER THERMAL POWER STATION seminar addict 2 2,173 05-09-2014, 10:36 PM
Last Post: seminar report asees
  Hydro power plants PPT seminar details 1 2,230 24-08-2014, 01:09 AM
Last Post: avantidarbhe
  A novel DC-AC Single Phase Resonant Inverter using soft switching boost seminar addict 1 1,441 19-03-2014, 01:38 AM
Last Post: Guest
  Siemens AG, Power Generation Germany seminar addict 2 2,825 09-04-2013, 10:46 AM
Last Post: computer topic
  power management using load shedding. seminar addict 2 1,960 13-03-2013, 02:44 PM
Last Post: computer idea
  THERMAL POWER PLANT project uploader 1 2,541 18-01-2013, 12:22 PM
Last Post: seminar details
  SOLAR POWER TOWER full report seminar details 1 2,334 30-11-2012, 01:39 PM
Last Post: seminar details

Forum Jump: