seminar report on piano key spillways for dams
#1
Wink 

Reply
#2
please get me seminar report on piano key wiers
Reply
#3

seminar report on piano key spillways for dams

Similar to labyrinth weirs, piano key (PK) weirs are folded in plan to increase discharge capacity for a given spillway channel width. Because of their configuration, PK weirs may be better suited than labyrinth weirs for applications where the weir footprint (length and/or width) dimensions are restricted (e.g., crest of gravity dams) as PK weirs can facilitate a significant amount of weir length relative to their footprint size. For channel applications without significant footprint restrictions, labyrinth and PK weirs may both represent viable spillway options. This paper provides an overview of some of the advantages and disadvantages of PK weirs, labyrinth weirs, and gated structures in channel applications and/or dam rehabilitation, including economic, structural, and hydraulic considerations. Two case studies are reviewed where a labyrinth weir or other type of control structure were constructed. The potential application of a PK weir was comparatively assessed for the same projects, had the option been available at the time of design. Free-flow spillways are simpler and saferthan gated ones, but the low specific flow of their traditional shapes requires high spilling nappe depths and thus huge losses of storage (100 x 109 m3 worldwide). A newly evolved shape of free-flow spillway (the "Piano Key weir") has the potential to increase the specific flow as high as fourfold at lower discharges. It could substantially increase, at low cost, the safety and the storage and/or the flood control efficiency of many existing as well as new dams. It is thus very advantageous to increase thespecific flow as much as possible. Some tens of existing spillways have been designed accordingly as vertical walls on a flat bottom, with a trapezoidal labyrinth layout which is much longer than the spillway length (often four times). They usually double the specific flow of an Ogee Spillway. Piano-Key Weir derives its name from its plan-form shape which looks like a ‘piano-key’. It is configured as polygonal walls such as to provide a much longer crest length than the conventional ogee spillways.
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Tagged Pages: piano key spillways for dams seminar report, piano key weir seminar report, yhsm inucbr 001, piano key weir, seminar report on spillway, disadvantages of piano key weir,
Popular Searches: topics for presentation on dams, free beginner piano, piano lessons for beginners pdf, ppt topics on dams and bridges, automatic water dams, how to start teaching piano, piano learner music,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  seminar topics on cfd ppt and full report pdf 1 22,206 02-05-2018, 06:48 PM
Last Post: hello990
  seminar report on 3d solar cells ppt paper presentation ppt seminars report on 3d solar cells ppt paper presentation ppt 5 43,085 15-04-2018, 08:39 AM
Last Post: Guest
  report on yii framework seminar 2 1,378 02-01-2018, 03:32 PM
Last Post: dhanabhagya
  seminar ppt on nanotechnology in horticulture with respect to fruit science 6 3,204 16-08-2017, 10:45 AM
Last Post: jaseela123d
  seminar report on public safety application enabled gps smartphone and android operating system 5 2,059 26-04-2017, 10:36 AM
Last Post: jaseela123d
  seminar report on wingate vpn 1 947 15-04-2017, 02:06 PM
Last Post: jaseela123d
  seminar money pad the future wallet wikipedia 1 1,164 13-04-2017, 12:19 PM
Last Post: jaseela123d
  seminar report on epidermal electronics systems 1 854 12-04-2017, 03:18 PM
Last Post: jaseela123d
  tubular skylight report for seminar 1 802 12-04-2017, 11:07 AM
Last Post: jaseela123d
  seminar paper example infant mortality and its effect 1 1,183 11-04-2017, 02:52 PM
Last Post: jaseela123d

Forum Jump: