DC MACHINES
#1

[attachment=5042]

prepared by:
Hatem Al-Ghannam


Introduction

-The stator of the dc motor has poles, which are excited by dc current to produce magnetic fields.
-In the neutral zone, in the middle between the poles, commutating poles are placed to reduce sparking of the commutator. The commutating poles are supplied by dc current.
-Compensating windings are mounted on the main poles. These short-circuited windings damp rotor oscillations
-The poles are mounted on an iron core that provides a closed magnetic circuit.
-The motor housing supports the iron core, the brushes and the bearings.
-The rotor has a ring-shaped laminated iron core with slots.
-Coils with several turns are placed in the slots. The distance between the two legs of the coil is about 180 electric degrees.
-The coils are connected in series through the commutator segments.
The ends of each coil are connected to a commutator segment.
-The commutator consists of insulated copper segments mounted on an insulated tube.
-Two brushes are pressed to the commutator to permit current flow.
-The brushes are placed in the neutral zone, where the magnetic field is close to zero, to reduce arcing.
-The rotor has a ring-shaped laminated iron core with slots.
-The commutator consists of insulated copper segments mounted on an insulated tube.
-Two brushes are pressed to the commutator to permit current flow.
-The brushes are placed in the neutral zone, where the magnetic field is close to zero, to reduce arcing.
-The commutator switches the current from one rotor coil to the adjacent coil,
-The switching requires the interruption of the coil current.
-The sudden interruption of an inductive current generates high voltages .
-The high voltage produces flashover and arcing between the commutator segment and the brush.


Reply
#2
Sad 

[attachment=6015]
MMME2104
Design & Selection of Mining Equipment
Electrical Component

DC Machines


Lecture Outline
• DC Generators
– Operating principle
– Separately excited generator
– Shunt generator
– Compound generator
• DC Motors
– Shunt motor
– Series motor
– Compound motor
– Starting and braking
– Basics of speed control

DC Generators: Operating Principle

The difference between AC and DC generators:
• AC generators use slip rings
• DC generators use commutators
Otherwise, the machine constructions are
essentially the same.

Induced voltage in a DC generator: E = B L v (Faraday’s Law)
For a DC generator, this equation can be manipulated to give:
Eo = C n Φ / 60
Eo = voltage between the brushes (V)
N = speed of rotation (rpm)
Φ = flux per pole (Wb)
C = total number of conductors on the armature*
*The number of conductors equals the number of slots (coils) times the
number of turns per coil times two

Neutral zones:
Neutral zones are those places on
the surface of the armature
where the flux density is zero.
When a generator operates at noload,
the neutral zones are
located exactly between the
poles.
No voltage is induced in a coil that
cuts through the neutral zone.
We always try to set the brushes
so they are in contact with coils
that are momentarily in a
neutral zone.
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Popular Searches: lubrication brushes, motorator brushes,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  Synchronous Machines smart paper boy 1 1,365 09-02-2012, 03:08 PM
Last Post: seminar paper
  BASIC CONCEPTS OF ROTATING ELECTRICAL MACHINES smart paper boy 0 2,927 30-08-2011, 04:37 PM
Last Post: smart paper boy
  Double-Stator Switched Reluctance Machines (DSSRM): Fundamentals and Magnetic Force seminar class 0 1,185 06-05-2011, 10:51 AM
Last Post: seminar class
  Effects of Induction Machines Dynamics on Power System Stability seminar class 0 1,356 04-05-2011, 12:07 PM
Last Post: seminar class
  CEDABMM (concurrent error detection on asynchronous burst mode machines) seminar class 0 813 17-03-2011, 11:08 AM
Last Post: seminar class
  Face Detection in images : Neural networks & Support Vector Machines computer science technology 0 2,282 26-01-2010, 11:40 PM
Last Post: computer science technology
  Fuzzy Logic based fault detection in induction machines using Lab view computer science technology 0 2,025 20-01-2010, 09:59 AM
Last Post: computer science technology

Forum Jump: