Synthetic Tests of Capacitive Current Switching Using a Test Vessel
#1

Abstract
According to the relevant IEC standards vacuumcircuit-breakers have to meet various needs, e.g. theinterruption capability, making operations, and dielectricstrength. Switching of capacitor banks, overhead lines, orcables leads to very small currents in comparison withshort-circuit currents. After current interruption thecircuit-breaker must withstand twice the peak value of thesystem voltage. Furthermore, restrikes can lead to voltagemultiplication. The conjunction of relatively smallbreaking currents with high voltage stress must beconsidered in detail.This work introduces a test arrangement for combinedtests of making operation, current interruption, anddielectric stress of a vacuum gap under capacitiveswitching condition. A test vessel permits investigations ofvarious contact materials and designs. It is connected to asynthetic test circuit which provides the appropriate testcurrents and capacitive voltage. Both the appearance ofpre-ignitions at contact closing and the behavior undercapacitive voltage stress after breaking are observed asindications of the contact surface conditions.
I. INTRODUCTION
Circuit-breakers have to fulfill diverse requirementsconcerning interruption capabilities and dielectricstrength. Typically a high switching duty and adistinctive dielectric strength are in the main focus ofdesign, construction, and testing of circuit-breakers. Thismeets with the needs of short-circuit currents andovervoltage stress respectively. Additionally switchingof capacitive loads i.e. capacitor banks, cable loads oroverhead lines, represents a specific operating conditionthat requires extensive performance. The testspecifications given by IEC standards [1] correspond tothese requirements.The connection of a capacitive load to the system leadsto inrush-currents of up to several kiloamperes atfrequencies significantly higher than the powerfrequency [2]. Typical currents at the interruption ofcapacitive loads are in the range of some tens of amperesto hundreds of amperes [1]. Subsequently the recoveryvoltage across the circuit-breaker rises up to twice thesystem voltage. Furthermore, in the event of a restrikeafter current interruption the capacitor can be reloadedcausing an increase of the trapped charge and followingan even higher voltage stress to the circuit-breaker [3, 4].Considering these operational conditions, the properties,the behavior, and the alteration of the contacts and theirsurface are taking centre stage. Accordingly a testarrangement was developed to examine various contactdesigns and materials.II. EXPERIMENTAL SET-UPThe synthetic test circuit as shown in Fig. 1 includes thetest switch STEST connected to the high current circuit(left) and the high voltage circuit (right). The former issupplying the test current for both the making and thebreaking operation by discharging the capacitor bank C1over either inductance LC or LO respectively. Therewiththe appropriate test currents of up to 4.5 kA at afrequency of 250 Hz for making tests and some 500 A at50 Hz frequency for breaking tests are generated. Thehigh voltage circuit supplies the capacitive recoveryvoltage up to 50 kV (50 Hz) which is applied to the testswitch STEST subsequent to a current interruption.For making tests the capacitor bank C1 is charged using aseparate charging system (not shown) while earthingswitch SG1 is in open position. The selector switch SLconnects the associated inductance LC providing afrequency of 250 Hz. The high current circuit isconnected to the test switch STEST by closing of makingswitch SM1. Closing of STEST leads to a dampedinrush-current flow accompanied by discharging of thecapacitor bank C1. The maximum peak value ofinrush-current is 4.5 kA at 20 kV charging voltage acrossC1.


Download full report
http://htee.tu-bs.de/forschung/veroeffen...ASN114.pdf
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Popular Searches: vessel details, seminar on immunological tests, capacitive sensing technology, capacitive sensors seminar reports, 3m projected capacitive technology, ppt of tests on 3phase induction motor, monitoring online tests through data visualization,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  Speech based password enabled devices switching system seminar class 1 2,627 24-01-2015, 05:23 AM
Last Post: Guest
  Automatic Railway Gate Control and Track Switching full report project topics 14 25,063 23-04-2013, 05:54 PM
Last Post: Ramachandra c
  SYNTHETIC APERTURE RADAR SYSTEM smart paper boy 1 1,034 10-12-2012, 03:07 PM
Last Post: seminar details
  Design of Hybrid Encoded Booth Multiplier with Reduced Switching Activity Technique seminar class 1 9,443 01-12-2012, 12:08 PM
Last Post: seminar details
  INFRARED SWITCHING OF ELECTRICAL APPLIANCES USING EMBEDDED CONTROLLER full report seminar topics 12 8,965 29-11-2012, 01:31 PM
Last Post: seminar details
  Constant-Current Battery Charger seminar class 2 1,694 09-11-2012, 11:53 AM
Last Post: seminar details
  TEST PLATFORM FOR SECURE WIRELESS COMMUNICATION USING XTEA computer science crazy 3 3,384 05-03-2012, 10:36 AM
Last Post: seminar paper
  AUTOMATED LIGHT SWITCHING CONTROL SYSTEM seminar surveyer 1 2,241 16-02-2012, 10:54 AM
Last Post: seminar paper
  A GPS Synchronized Current Differential Protection of Transmission Lines seminar class 1 1,643 15-02-2012, 12:52 PM
Last Post: seminar paper
  INTELLIGENT BATTERY CHARGING USING PIC16F73 MICRO CONTROLLER FOR MISSILE TEST EQUIPME computer science crazy 1 3,428 09-01-2012, 02:51 PM
Last Post: yuvagiri

Forum Jump: