lightning protection zones
#1

i need full seminar report on this topic with ppt....please send soon
Reply
#2
The development of the equipment and systems sensitive to lightning electromagnetic impulse (LEMP) requires more efficient protection measures within a new lightning protection zones (LPZ) concept. effective selection and application of these measures should be based on a probabilistic approach which may contain procedures like:
-recognition of all kinds of lightning influence on the structure and its sensitive equipment;
-selection of protection measures in respect of highest value of risk component and LPZ concept
-assessment of lightning hazard involving structure features and protection measures efficiency;
The key-point in the analysis of lightning protection devices is the determination of the protection zone. The boundary element analysis of the protection zone of a metallic post, as one of the most commonly used lightning protection devices is the common method to determine the LPZ of the post. Protection against LEMP is based on the concept of LPZ,
the lightning protection zones, characterised by
significant changes of the LEMP severities compatible
with the immunity level of the internal systems.(LEMP:
lightning electromagnetic impulses).
The following
LPZ are defined for full LPM systems:
*outer zones:
- LPZ 0 = zone endangered by unattenuated lightning
magnetic and electric field and by surges up to full or
partial lightning current. This region is again divided into:
1)LPZ 0A endangered by direct lightning strikes, by surges
up to full lightning current and by full lightning field
2)LPZ 0B protected against direct lightning strikes but
endangered by surges up to partial lightning current and
by full magnetic field

inner zones (protected against direct lightning strikes):
- LPZ 1:Here the surges are limited by current sharing and
by SPD at the boundary; the lightning field can be
attenuated by spatial shielding;
- LPZ 2, ¦ N :In this region, the surges are further limited by current
sharing and SPD at the boundary; the lightning field is
usually attenuated by spatial shielding.

For moe, visit this pdf:
[attachment=2628]
Reply
#3
to get information about the topic lightning protection zones full report ppt and related topic refer the page link bellow

http://studentbank.in/report-lightning-protection-zones

http://studentbank.in/report-lightning-p...nes--16466

http://studentbank.in/report-surge-prote...ices--7894

http://studentbank.in/report-lightning-p...?pid=32457
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Popular Searches: lightning protection zones ppt, lightning protection ethernet, lightning protection zones, lightning protection certification, lightning surge protection, irc sp 55 2001 guidelines for safety in construction zones free download, lightning protection equipment suppliers,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  ppt on protection of transmission lines using gps rashid 9 10,494 27-07-2017, 12:09 PM
Last Post: NEHA BAIJU
  ppt of street lightning based on sensors using plc and scada 1 583 16-04-2016, 10:52 AM
Last Post: dhanabhagya
  lightning frequency arrester ppt 1 570 08-04-2016, 11:11 AM
Last Post: dhanabhagya
  transformer protection panel dur-e-shana sikandar 11 8,993 18-02-2016, 02:25 PM
Last Post: seminar report asees
  impact of lightning on buildings and its remedial measures 1 910 05-07-2014, 10:29 PM
Last Post: seminar report asees
  ppt on surge current protection using superconductor rosyranipatel123 9 7,952 17-02-2014, 01:02 AM
Last Post: Guest
Question Protection Of Transmission Systems By Using The Global Positioning System manish kateshiya 3 2,070 06-07-2013, 03:00 PM
Last Post: Guest
  motor protection 1 936 06-03-2012, 11:09 AM
Last Post: seminar paper
  protection of transmission lines by using gps guddan 1 1,096 05-03-2012, 11:30 AM
Last Post: seminar paper
  new technique for protection of a transmission line using gps 0 892 27-02-2012, 05:04 PM
Last Post: Guest

Forum Jump: