¢ HTS Fault Current Limiters
By: Leanne Naidoo & Pranesh Sarjoodei
¢ Introduction
¢
¢
¢
Fault Current ,Circuit Breakers

¢ Fault currents are unanticipated power disturbances in the utility grid caused by lightning etc
¢ This causes circuit breakers to open and close. Circuit breaker will remain open in wait for repair crew.
¢ Until the power is restored, an outage occurs.
¢ In today™s electricity dependant economy, significant hardships and economic losses occur during the outages


¢ What is a FCL?

¢ When lightening or some other event causes a fault condition, the circuit breakers shut down the system to protect it from severe damage.
¢ A large HTS FCL acts as an energy absorbing device, reducing the current surge and the duty on circuit breakers to isolate the fault.
HTS fault current limiter based on melt-cast BSSCO, system design and laboratory test



¢ How Does HTS FCL Work?

¢ Takes adv of superconducting phenomena.
¢ At low temp, resistance is negligible, allowing high current transfer.
¢ When low temp are allowed to rise the resistance increases and limits current flow, hence protecting the downstream equipment from high/fault currents.
¢ Basically a variant of a transformer, this would significantly reduce fault currents and lower switch or breaker ratings in multiple circuit systems to the offending source within a given circuit.


¢ Benefits of a HTS FCL

¢ Reduces high currents.
¢ Fast Response with no active control.
¢ Invisible to grid during normal operation
¢ No need for expensive circuit breakers with high interrupting capability.
¢ FCL in transformers can run 10-20 times the steady state design current. HTS FCL can reduce this to levels not exceeding 3-5 times the steady state design current


¢ Comparison To Conventional Solutions

¢ System fault current level rise with added generators loads, etc..
¢ Solutions?


1.Circuit breaker technology near 80 kA upper limit. Interrupt power. Electric service is shut down unless an alternate path is found
Explosive fault limiting fuses require service call to be replaced.
Series reactors lossy, bulky, contribute to grid, costly power systems.



2. HTS fault current limiters (FCLs) :

Reduction of fault currents by a factor of 3-10- Single shot protection for 5-10 cycles.
Automatic resetting after a recovery time of sec to min.
Distribution and transmission voltages up to ~138 kV
HTS FCLs“an attractive solution to a critical utility problem




¢ Types of HTS FCL

¢ Types of HTS FCL™s :
¢ Bridge FCL
¢ Inductive FCL.
¢ Resistive FCL
¢ 1st generation (1G)HTS wire
¢ 2nd generation (2G) HTS wire
¢ Resistive HTS FCL can address critical utility issues cost-effectively
¢ 2G HTS wire is optimum for a practical resistive FCL


¢ MFCL-An Improved HTS FCL
¢ MFCL (Matrix FCL)
¢ MFCL Design- columns :current limiting impedance required
¢
¢
¢
¢ .
¢ MFCL Test Results

¢ 1. Good sharing among current limiting elements
¢ 2. No excessive stress on any element
¢ 3. Fast dynamic Res. development & 1st peak limitation
¢ 4. Fast current transfer from HTS elements to shunt coils Reduces stress on HTS Voltage elements during fault



¢ Inductive HTS FCL

¢ Limiter suitable for high-current circuits (IL > 1000 A)
¢ A copper winding WCu is inserted in the circuit and is coupled to an HTS winding WHTS
¢ Normal operation, a zero impedance is reflected to the primary
¢ Resistance developed in the HTS winding during a fault is reflected to the primary and limits the fault.
¢ The large current is induced in the secondary winding which loses superconductivity.



¢ Inductive HTS FCL


¢ Series Resistive HTS FCL

¢ Exploits the nonlinear resistance of superconductors in a direct way.
¢ A superconductor is inserted in the circuit & for a full-load current of IFL, the superconductor would be designed to have a critical current of 2IFL or 3IFL.
¢ Fault current pushes the superconductor into a resistive state & resistance R appears in the circuit.
¢ The superconductor in its resistive state can also be used as a trigger coil, pushing the bulk of the fault current through a resistor or inductor.


¢ Resistive HTS FCL
¢ Swiss Hydro Power Plant Using Resistive HTS FCL


¢ The Market

¢ HTS Fault Current Limiters (FCLs) address the market pull to cost-effectively correct fault current over-duty problems at the transmission voltage level of 138kV and higher
¢ The HTS FCLs will reduce the available fault current to alower, safer level (~50%,possibly greater) so that existing switchgear can still protect the grid
¢ HTS FCLs are anatural compliment to AC HTS cable systems


¢ Design of a SFCL
¢ Limits fault currents to <60% of the steady state prospective fault current


¢ British FCL Project

¢ The new £2.5m FCL and intelligent grid management project is lead by Rolls Royce Electrical Systems and Strategic Research Centre, with the finished machine expected to be installed at Scottish Power's test facility; the project involves Diboride Conductors, the University of Manchester, Strathclyde University, Hyper Tech Research (Ohio) and Scientific Magnetics (Oxford).
¢ The successful project which finished earlier in 2007 developed a single-phase 220V/1kA FCL using an innovative solid-state and cryocooler cooling system, operating at 24-30K.
¢ It validated current sharing between parallel superconducting wires during FCL operation



¢ Technology Status

¢ A majority of American Superconductor's second generation (2G) high-temperature superconductor (HTS) wire, known as 344 superconductors, is being used in the development of fault current limiters.
¢ There has been strong demand for fault current limiters among domestic and overseas utilities.
¢ American Superconductor™s fault current limiter product development effort with Siemens, has at least seven other electrical equipment developers in four countries who are now utilizing 344 superconductors to develop fault current limiters.
¢ This is a vast new market opportunity for HTS that the U.S. Department of Energy forecasts to be in the billions of dollars.
¢ Technology Status
¢ HTS FCL Develepmont


¢ References

¢ To learn more about FCLs please see http://amsuperproducts/htsWire/FaultCurrentLimiters.cfm and http://electricity.doe.gov/
¢ Siemens' activities on superconducting components and equipment please see http://industry.siemensmarine/EN/product...ations.htm and http://siemensindex.jsp?sdc_p=cd1034230flmn1031937o1067086ps4u&sdc_si d=14017264143&
¢ http://amsuperproducts/htsWire/2GWireTechnology.cfm
¢ http://wtecloyola/scpa/04_03.htm
¢ http://sandiego.edu/EPIC/news/documents/Bradshaw.pdf
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Popular Searches: ppt on hts generator, hts power cables seminar report, report of hts fault current limiter, limiters, ppt on hts power cables, superconductor as a surge current limiters seminar report, lfm cfm,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  Surge current protection using superconductors computer science crazy 9 11,017 16-03-2016, 12:03 AM
Last Post: computer science crazy
  Surge Current Protection Using Superconductors pradeep.srivatsa 10 10,231 16-03-2016, 12:03 AM
Last Post: computer science crazy
Star Surge current protection using superconductors computer science crazy 13 8,321 02-02-2015, 04:04 PM
Last Post: Guest
  Transformers Internal Incipient Fault Model computer science crazy 5 5,706 10-11-2014, 11:05 PM
Last Post: jaseela123d
  Fault Locating In Undegrounded And High Resistance GroundedSystems computer science crazy 12 14,563 15-04-2013, 02:15 PM
Last Post: Guest
  TRANSMISSION LINE FAULT MONITORING seminar class 2 3,592 13-01-2013, 10:29 PM
Last Post: [email protected]
  High-voltage direct current computer girl 0 1,323 07-06-2012, 04:58 PM
Last Post: computer girl
  Aging Effect on Leakage Current Flow in Wooden Poles computer girl 0 1,163 06-06-2012, 05:44 PM
Last Post: computer girl
  Magneto-optical current transformer technology (MOCT) computer science crazy 9 13,279 27-02-2012, 12:41 PM
Last Post: seminar paper
  optical technology in current measurement seminarsense 3 6,905 14-02-2012, 07:16 AM
Last Post: shankara chary

Forum Jump: