UNINTRUPTABLE POWER SUPPLY (U.P.S)
#1

[attachment=12585]
INTRODUCTION:
An uninterruptible power supply, also uninterruptible power source, UPS or battery/flywheel backup, is an electrical apparatus that provides emergency power to a load when the input power source, typically the utility mains, fails. A UPS differs from an auxiliary or emergency power system orstandby generator in that it will provide instantaneous or near-instantaneous protection from input power interruptions by means of one or more attachedbatteries and associated electronic circuitry for low power users, and or by means of diesel generators and flywheels for high power users. The on-battery runtime of most uninterruptible power sources is relatively short—5–15 minutes being typical for smaller units—but sufficient to allow time to bring an auxiliary power source on line, or to properly shut down the protected equipment.
While not limited to protecting any particular type of equipment, a UPS is typically used to protect computers, data centers, telecommunicationequipment or other electrical equipment where an unexpected power disruption could cause injuries, fatalities, serious business disruption and/or data loss. UPS units range in size from units designed to protect a single computer without a video monitor (around 200 VA rating) to large units powering entire data centers, buildings, or even cities.[1]
Common power problems
The primary role of any UPS is to provide short-term power when the input power source fails. However, most UPS units are also capable in varying degrees of correcting common utility power problems:
1. Power failure: defined as a total loss of input voltage.
2. Surge: defined as a momentary or sustained increase in the mains voltage.
3. Sag: defined as a momentary or sustained reduction in input voltage.
4. Spikes, defined as a brief high voltage excursion.
5. Noise, defined as a high frequency transient or oscillation, usually injected into the line by nearby equipment.
6. Frequency instability: defined as temporary changes in the mains frequency.
7. Harmonic distortion: defined as a departure from the ideal sinusoidal waveform expected on the line.
UPS units are divided into categories based on which of the above problems they address[dubious – discuss], and some manufacturers categorize their products in accordance with the number of power related problems they address.
Technologies
The general categories of modern UPS systems are on-line, line-interactive or standby. An on-line UPS uses a "double conversion" method of accepting AC input, rectifying to DC for passing through therechargeable battery (or battery strings), then inverting back to 120V/240V AC for powering the protected equipment. A line-interactive UPS maintains the inverter in line and redirects the battery's DC current path from the normal charging mode to supplying current when power is lost. In a standby ("off-line") system the load is powered directly by the input power and the backup power circuitry is only invoked when the utility power fails. Most UPS below 1 kVA are of the line-interactive or standby variety which are usually less expensive.
For large power units, dynamic uninterruptible power supplies are sometimes used. A synchronous motor/alternator is connected on the mains via a choke. Energy is stored in a flywheel. When the mains power fails, an Eddy-current regulation maintains the power on the load. DUPS are sometimes combined or integrated with a diesel-generator[clarification needed], forming a diesel rotary uninterruptible power supply, orDRUPS.
A fuel cell UPS has been developed in recent years using hydrogen and a fuel cell as a power source, potentially providing long run times in a small space.
Offline / standby
Offline / standby UPS. Typical protection time: 0–20 minutes. Capacity expansion: Usually not available
The Offline / Standby UPS (SPS) offers only the most basic features, providing surge protection and battery backup. With this type of UPS, a user's equipment is normally connected directly to incoming utility power with the same voltage transient clamping devices used in a common surge protected plug strip connected across the power line. When the incoming utility voltage falls below a predetermined level the SPS turns on its internal DC-AC inverter circuitry, which is powered from an internal storage battery. The SPS then mechanically switches the connected equipment on to its DC-AC inverter output. The switchover time can be as long as 25 milliseconds depending on the amount of time it takes the Standby UPS to detect the lost utility voltage. Generally speaking, dependent on the size of UPS connected load and the sensitivity of the connected equipment to voltage variation, the UPS will be designed and/or offered (specification wise) to cover certain ranges of equipment, i.e. Personal Computer, without any obvious dip or brownout to that device.
Line-interactive
Line-Interactive UPS. This illustration shows an isolated transformer, not an autotransformer, and does not show the way that the charger and inverter are connected to the secondary side of the same transformer. Typical protection time: 5–30 minutes. Capacity expansion: Several hours
The Line-Interactive UPS is similar in operation to a Standby UPS, but with the addition of a multi-tap variable-voltage autotransformer. This is a special type of electrical transformer that can add or subtract powered coils of wire, thereby increasing or decreasing the magnetic field and the output voltage of the transformer.
This type of UPS is able to tolerate continuous undervoltage brownouts and overvoltage surges without consuming the limited reserve battery power. It instead compensates by automatically selecting different power taps on the autotransformer. Depending on the design, changing the autotransformer tap can cause a very brief output power disruption,[citation needed] which may cause UPSs equipped with a power-loss alarm to "chirp" for a moment.
This has become popular even in the cheapest UPSs because it takes advantage of components already included. The main 50/60 Hz transformer used to convert between line voltage and battery voltage needs to provide two slightly different turns ratios: one to convert the battery output voltage (typically a multiple of 12 V) to line voltage, and a second one to convert the line voltage to a slightly higher battery charging voltage (such as a multiple of 14 V). Further, it is easier to do the switching on the line-voltage side of the transformer because of the lower currents on that side.
To gain the buck/boost feature, all that is required is two separate switches so that the AC input can be connected to one of the two primary taps, while the load is connected to the other, thus using the main transformer's primary windings as an autotransformer. Note that the battery can still be charged while "bucking" an overvoltage, but while "boosting" an undervoltage, the transformer output is too low to charge the batteries.
Autotransformers can be engineered to cover a wide range of varying input voltages, but this requires more taps and increases complexity, and expense of the UPS. It is common for the autotransformer to only cover a range from about 90 V to 140 V for 120 V power, and then switch to battery if the voltage goes much higher or lower than that range.
In low-voltage conditions the UPS will use more current than normal so it may need a higher current circuit than a normal device. For example to power a 1000 watt device at 120 volts, the UPS will draw 8.32 amps. If a brownout occurs and the voltage drops to 100 volts, the UPS will draw 10 amps to compensate. This also works in reverse, so that in an overvoltage condition, the UPS will need fewer amps of current.
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Popular Searches: improvements in unintruptable, overvoltage,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  Solar power plant full report seminar class 2 3,370 11-11-2015, 01:49 PM
Last Post: seminar report asees
  SOLAR POWER WATER PUMPING SYSTEM seminar class 8 6,461 20-08-2015, 03:06 PM
Last Post: seminar report asees
  Micro Controller based Power Theft Identifier seminar projects crazy 26 14,343 17-10-2014, 08:21 PM
Last Post: jaseela123d
  Artificial intelligence in power station seminar class 6 7,106 21-09-2014, 11:15 PM
Last Post: Guest
  PIC BASED INTELLIGENT TRACKING SYSTEM USING SOLAR POWER project report helper 3 4,139 27-03-2014, 05:35 AM
Last Post: Guest
  POWER THEFT IDENTIFICATION WITH MAINTAINING MAXIMUM DEMAND USING GSM TEHNOLOGY project topics 4 5,578 17-02-2014, 04:47 AM
Last Post: Guest
  ELECTROSTATIC MICRO POWER GENERATOR FROM LOW FREQUENCY VIBRATION SUCH AS HUMA seminar surveyer 2 3,966 14-09-2013, 09:53 AM
Last Post: computer topic
  CONTROL AND ANALYSIS OF A UNIFIED POWER FLOW CONTROLLER project topics 5 3,762 24-06-2013, 08:41 PM
Last Post: lenovouser73
  Automatic power meter reading system using GSM network Electrical Fan 16 14,406 11-04-2013, 11:02 AM
Last Post: computer topic
  power system projects electronics seminars 20 35,555 12-02-2013, 11:09 AM
Last Post: seminar details

Forum Jump: