IC Controlled Emergency Light with Charger
#1


By
R. RAINA

The circuit shown here is that of the IC controlled emergency light. Its main features are: automatic switching-on of the light on mains failure and battery charger with overcharge protection. When mains is absent, relay RL2 is in deenergised state, feeding battery supply to inverter section via its N/ C contacts and switch S1. The inverter section comprises IC2 (NE555) which is used in stable mode to produce sharp pulses at the rate of 50 Hz for driving the MOSFETs. The output of IC3 is fed to gate of MOSFET (T4) directly while it is applied to MOSFET (T3) gate after inversion by transistor T2. Thus the power amplifier built around MOSFETs T3 and T4 functions in push-pull mode. The output across secondary of transformer X2 can easily drive a 230-volt, 20-watt fluorescent tube. In case light is not required to be on during mains failure, simply flip switch S1 to off position. Battery overcharge preventer circuit is built around IC1 (LM308). Its non inverting pin is held at a reference voltage of approximately 6.9 volts which is obtained using diode D5 (1N4148) and 6.2-volt zener D6. The inverting pin of IC1 is connected to the positive terminal of battery. Thus when mains supply is present, IC1 comparator output is high, unless battery voltage exceeds 6.9 volts. So transistor T1 is normally forward biased, which energises relay RL1. In this state the battery remains on charge via N/O contacts of relay RL1 and current limiting resistor R2. When battery voltage exceeds 6.9 volts (overcharged condition), IC1 output goes low and relay RL1 gets deenergised, and thus stops further charging of battery. MOSFETs T3 and T4 may be mounted on suitable heat sinks.

courtesy:electronicsforu.com

read more
http://electronicsforuefylinux/circuit/IC.pdf
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Popular Searches: mini project on emergency light charger*, emergency light bar led, emergency light based nokia mobile charger diagram, ic controlled emergency lamp with charger circuit mini project, emergency tube light, conclusion of automayi emergency light circuit, mini emergency light abstract download,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  INTEGRATED EMERGENCY RESPONSE SYSTEM USING EMBEDDED SYSTEM seminar presentation 1 9,162 19-11-2018, 08:40 PM
Last Post:
  Military combat robot wireless controlled. Camera helps keeping an eye on border. seminar class 6 11,396 09-06-2017, 10:27 AM
Last Post: jaseela123d
  AUTOMATIC STREET LIGHT CONTROL WITH SENSOR TECHNOLOGY seminar class 2 11,754 22-05-2017, 11:07 AM
Last Post: yasminoth93
  AUTOMATIC STREET LIGHT CONTROL-EMBEDDED BASED PROJECT project topics 18 30,417 11-02-2016, 02:03 PM
Last Post: seminar report asees
  Wireless based Automatic dam water level control shutter open /closed with emergency smart paper boy 4 11,462 11-09-2015, 02:00 PM
Last Post: seminar report asees
  NIGHT LIGHT SAVER computer science crazy 6 4,544 22-02-2015, 12:49 AM
Last Post: Guest
  COIN BASED MOBILE CHARGER full report seminar class 25 23,044 08-12-2014, 11:40 PM
Last Post: seminar report asees
  Automatic Room light Controller with Visitor Counter project topics 26 17,606 12-03-2014, 07:22 PM
Last Post: computer topic
  Automatic Street Light Control System seminar surveyer 7 13,526 25-02-2014, 12:18 AM
Last Post: Guest
  AUTOMATIC STREET LIGHT CONTROL USING LDR full report seminar class 18 37,430 04-08-2013, 06:21 AM
Last Post: Guest

Forum Jump: