advantages of water level controller using 8051 microcontroller wikipedia
#1

Plz send me advantages of water level controller using 8051
Reply
#2

In our daily lives, we often use different types of sensors in various electronic devices such as proximity sensor-mobile phone, motion sensor-automatic door operating system, temperature sensor-automatic fan speed control, sensor LDR Automatic street light System or automatic outdoor lighting system, and so on. Similarly, to prevent overflow of water in the tank above or in the water vessel, we can use the electronic circuit based on ultrasonic sensor. This article discusses the ultrasonic water level controller using 8051.

Water Level Controller

The water level controller, the name itself indicates that an electronic device or circuit kit used to control the water level can be referred to as a water level controller. It is difficult to know the level of water in the tank above, so that water waste can occur frequently. To conserve water, avoid overflow of water in the tank above that can cause loss of water, loss of electrical energy, etc. Therefore, the 8051 micro-controller ultrasonic water level controller is an innovative electronic project application to control the water level.


[Image: 4.jpg]

The level sensor probes for the upper tank are connected to port 2 of the microcontroller via transistors. Take a look at the sensor probe arrangement for the tank above in Fig1. A positive voltage supply probe goes to the bottom of the tank. The probes for detecting 1/4, 1/2, 3/4 and FULL levels are placed with equal spacing one by one above the lower positive probe. Consider the highest (full-level) probe, its other end is connected to the base of transistor Q4 through resistor R16. Whenever the water rises to full level, the current flows to the base of transistor Q4, which turns it ON and therefore its collector voltage goes down. The Q4 manifold is connected to P2.4 and a low voltage in P2.4 means that the overload tank is not FULL. When the water level passes below the full-level probe, the Q2 base opens by turning it OFF. Now your collector voltage goes high and high in P2.4 means the tank is not full. The same applies to other sensor probes (3/4, 1/2, 1/4) and the microprocessor understands the current level by scanning the access pins P2.4, P2.5, P2.6 and P2.7 . All these port pins are high (all sensor probes are open) means the tank is empty.

The P0.5 port pin is used to control the pump. Whenever it is necessary to start the pumping, the controller makes P0.5 under which causes the transistor Q6 to activate, which in turn activates the relay K1 that switches the pump. The d6 LED also illuminates indicating that the engine is running. LED D7 is the low power indicator. When the water level in the sump tank goes down, the controller makes P0.7 below which causes the D7 LED to glow.
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Popular Searches: advantages and disadvantages of automatic water level controller, datasheet of water level control using 8051 microcontroller, water level controller using 8051 block diagram, project report on solar tracking system using microcontroller 8051 wikipedia, water level monitoring and controller using microcontroller circuit, flow chart for water level controller using 8051, washing machine control of 8051 microcontroller wikipedia,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  advatages disadvantages of microcontroller based anesthesia injector 4 2,560 29-06-2018, 10:19 PM
Last Post: Guest
  program code of solar tracking system using 8051 microcontroller 6 23,387 03-05-2018, 09:30 PM
Last Post: Guest
Smile mesotechnology inventions advantages and disadvantages 1 8,387 03-05-2018, 09:23 AM
Last Post: Guest
  readings of hollow prism for water, kerosene oil, glycerine, turpentine 2 3,426 04-04-2018, 05:43 PM
Last Post: Guest
  renewable energy design application in water cooler ppt 1 9,115 16-03-2018, 06:04 PM
Last Post: Guest
  water level indicator circuit using 8085 microprocessor ppt 3 13,714 12-02-2018, 04:33 PM
Last Post: dhanabhagya
  solar water purification by using thermal method pdf file 2 13,191 12-02-2018, 03:44 PM
Last Post: dhanabhagya
  ledger account and trial balance of any business concern with the help of a journal wikipedia 2 2,421 31-01-2018, 06:15 PM
Last Post: [email protected]
  nanofiltration in water supply system ppt 3 1,643 02-01-2018, 02:56 PM
Last Post: dhanabhagya
  anti plastic campaign in india wikipedia 10 31,518 29-12-2017, 09:44 AM
Last Post: jaseela123d

Forum Jump: