shunt active filter based on voltage detection for harmonic termination of a radial p
#1

ABSTRACT

This paper focuses on a shunt active filter based on the detection of harmonic voltages at the point of installation. The objective of the active filter is to attenuate harmonic propagation resulting from series/parallel resonance between capacitors for power factor correction and line inductors in a power distribution line. The active filter acts as a low resistor to the external circuit for harmonic frequencies, and it is installed on the end bus of the power distribution line, just like a 50 O terminator installed on the end terminal of a signal transmission line. Therefore, the function of the active filter is referred to as harmonic termination in this paper. Experimental results obtained from a laboratory system rated at 200 V and 20 kW verify that the active filter for the purpose of harmonic termination has the capability of harmonic damping throughout the power distribution line

INTRODUCTION
NONLINEAR loads such as high-power diode/thyristor rectifiers, cycloconverters, and arc furnaces draw nonsinusoidal currents from utility grids. A single low-power diode rectifier used as a utility interface in an electric appliance produces a negligible amount of harmonic current. However, multiple low-power diode rectifiers can inject a large amount of current harmonics into power distribution systems. These harmonic-producing loads contribute to the degradation of power quality in transmission/distribution systems.

for full report
please read http://ieeexplore.ieeeiel5/28/16612/0076...ber=767015
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Popular Searches: radial lighting circuit diagram, document for precise termination contion of probabilistic packet marking algorithm, a precise termination condition abstract, cycloconverters, circuit diagram radial circuit, automatic radial driling machine, tcp connection termination ppt,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  Electric field Optimization of High Voltage Electrode Based On Neural Networks computer science crazy 2 10,110 01-01-2018, 11:56 AM
Last Post: dhanabhagya
  A Neural-Network-Based Space-Vector PWM Controller for Voltage-Fed Inverter Inducti project report helper 1 8,929 07-09-2015, 06:23 PM
Last Post: hafsa_012
Music TECHNIQUE FOR ONLINE DETECTION OF SHORTS IN FIELDS OF TURBINE GENERATOR ROTOR seminar projects crazy 8 7,984 27-09-2014, 09:55 PM
Last Post: seminar report asees
  Voltage Stability Improvement using Static Var Compensator in Power Systems project report tiger 4 13,381 12-07-2013, 11:29 AM
Last Post: computer topic
  Voltage Swell and Overvoltage Compensation Wifi 2 9,282 12-07-2013, 10:50 AM
Last Post: computer topic
Question COMPENSATION OF HARMONIC CURRENTS UTILIZING AHC seminar projects crazy 1 2,069 21-02-2013, 12:09 PM
Last Post: PESXPLORE123
  DYNAMIC VOLTAGE RESTORER seminar surveyer 7 15,153 15-02-2013, 10:17 AM
Last Post: seminar details
  compensation of harmonic currents utilizing AHC nmstuffs 4 3,040 08-02-2013, 03:27 PM
Last Post: Guest
  Digital Testing of High Voltage Circuit Breaker project topics 13 12,191 24-10-2012, 03:28 PM
Last Post: seminar details
  Variable Voltage And Variable Frequency drives full report seminar presentation 2 5,639 04-10-2012, 12:20 PM
Last Post: seminar details

Forum Jump: