Hi am abi i would like to get details on seminar report high voltage testing of transformer free .. seminar report high voltage testing of transformer free will be available here and now i am living at ......... and i last studied in the college/school ......... and now am doing ....i need help on ......etc
Reply
#2
Hi am abinash g i would like to get details on high voltage testing of transformer pdf on seminar topics .. high voltage testing of transformer pdf on seminar topics will be available here and now i am living at ......... and i last studied in the college/school ......... and now am doing ....i need help on ......etc
Reply
#3

High Voltage Transformer

Such transformers are normally used in high voltage laboratory for testing purpose. This transformer is subjected to transient voltages and surges during their normal operation when the insulation under test breaks down. To withstand these impulse voltages, the insulation of transformer is carefully designed. This high voltage transformer is single phase, core type. This type of transformer is generally oil immersed. Bakelite sheets are used for separating high tension and low tension winding. The high voltage transformers used for HT cable testing purpose are to supply also sufficient electric current and that is why the cooling system of these transformers is very carefully designed. Special cares also to be taken for voltage regulation of transformers. For insulator testing purposes, the required current is very less but, while the insulator breaks down during testing, there would flow huge current through the transformer. To limit this current, a high resistance is connected in series with transformer. As the current required is very less during insulation testing, this high voltage transformer needs not to have high KVA ratings. The table below shows, the rating of transformer used for various testing purposes.

Up to voltage 500 KV, generally single unit of high voltage transformer is used. But for higher voltage rating more than one transformer, are connected in cascade to produce required high voltage. Actually for getting such high voltage, a single transformer has to be very huge in size which is not at all economical.


High Voltage Testing Procedure
Electrical equipment must be capable of withstanding overvoltages during operation. Thus by suitable testing
procedure we must ensure that this is done.
High voltage testing can be broadly classified into testing of insulating materials (samples of dielectrics) and
tests on completed equipment.
The tests carried out on samples of dielectric consist generally of the measurement of permittivity, dielectric loss
per unit volume, and the dielectric strength of the material. The first two can be measured using the High
Voltage Schering Bridge.
The tests carried out on completed equipment are the measurement of capacitance, the power factor or the total
dielectric loss, the ultimate breakdown voltage and the flash-over voltage. The breakdown voltage tests on
completed equipment is only done on a few samples since it permanently damages and destroys the equipment
from further use. However since all equipment have to stand up to a certain voltage without damage under
operating conditions, all equipment are subjected to withstand tests on which the voltage applied is about twice
the normal voltage, but which is less than the breakdown voltage.
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Popular Searches: seminar based on radiographic testing ppt for download, transformer seminar report, transformer ppt free download, seminar on voltage doubler, high voltage testing of transformer report, seminar penetration testing seminars, seminar ppt on high voltage ac free download pdf,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  seminar on movable bridge pdf 0 5,244 05-11-2020, 10:32 PM
Last Post:
  seminar topic for bca download 1 6,961 14-11-2018, 09:04 PM
Last Post:
  green manufacturing full seminar report download 0 6,086 10-11-2018, 10:54 AM
Last Post: Guest
  list of seminar topics in botany 0 6,480 06-11-2018, 04:25 PM
Last Post: Guest
  software testing lab viva questions and answers vtu 0 5,284 30-10-2018, 02:09 AM
Last Post: Guest
  seminar on 132 33 kv substation 0 5,918 29-10-2018, 12:23 PM
Last Post: Guest
  liquid electricity technical seminar ppt 0 6,218 19-10-2018, 10:52 PM
Last Post: Guest
  seminar topics on hydrobiology 0 5,922 19-10-2018, 02:02 PM
Last Post: Guest
  fly ash bricks seminar report 0 5,801 19-10-2018, 11:06 AM
Last Post: Guest
  diamond ultimate semiconductor seminar report pdf 0 6,214 18-10-2018, 11:41 AM
Last Post: Guest

Forum Jump: