self supported chimney weight calculation
#1

top dia 2 mtrs bottom dia 4000 need weight of self supported chimney
Reply
#2
Sir I am trying to get my pay slip online for the month of August
Reply
#3
Most of the industrial steel chimneys are tall structures with circular cross-sections. Such
slender, lightly damped structures are prone to wind-exited vibration. Geometry of a self
supporting steel chimney plays an important role in its structural behaviour under lateral
dynamic loading. This is because geometry is primarily responsible for the stiffness
parameters of the chimney. However, basic dimensions of industrial self supporting steel
chimney, such as height, diameter at exit, etc., are generally derived from the associated
environmental conditions. To ensure a desired failure mode design code (IS-6533: 1989
Part 2) imposes several criteria on the geometry (top-to-base diameter ratio and height-tobase
diameter ratio) of steel chimneys. The objective of the present study is to justify the
code criteria with regard to basic dimensions of industrial steel chimney.
A total of 66 numbers self supporting steel flared unlined chimneys with different top-to-base
diameter ratio and height-to-base diameter ratio were considered for this study. The thickness
of the chimney was kept constant for all the cases. Maximum bending moment and stress for
all the chimneys were calculated for dynamic wind load as per the procedure given in
IS 6533: 1989 (Part 2) using MathCAD software. Also the results were verified with the
finite element analysis using commercial software ANSYS. Basic wind speed of 210 km/h which corresponds to costal Orissa area is considered for these calculations. Maximum base
moments and associated steel stresses were plotted as a function of top-to-base diameter ratio
and height-to-base diameter ratio. The results obtained from this analysis do not agree with
the code criteria.
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Popular Searches: boiler chimney height calculation, boiler chimney height calculation formula, is 6533 1989, texas state supported, 25m self supporting chimney design, unicode asp files are not supported, ppt self supporting steel chimney design,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  Request for mini hacksaw driven by beam engine calculation 0 8,759 30-03-2021, 02:13 AM
Last Post:
  industrial self supporting chimney design calculation 0 8,264 11-02-2021, 05:11 PM
Last Post:
  Peradventure you continually wanted to believe a cat-house self-governed 0 604 05-10-2019, 12:37 PM
Last Post:
  self introduction format hindi pdf 0 5,380 09-08-2018, 07:25 AM
Last Post: Guest
  saddle support design calculation excel 0 558 07-07-2018, 01:33 PM
Last Post: Guest
  Mgu index mark calculation 0 616 28-06-2018, 09:11 AM
Last Post: Guest
  self parking system project 0 447 25-04-2018, 06:32 PM
Last Post: Guest
  baja transmission design calculation ppt 0 506 18-04-2018, 07:21 PM
Last Post: Guest
  ppt of self rechargeable paper thin film batteries 0 460 16-04-2018, 08:09 PM
Last Post: Guest
  pneumatic vice design calculation pdf 0 427 11-04-2018, 03:00 PM
Last Post: Guest

Forum Jump: