WASTE CHILL RECOVERY HEAT EXCHANGER FULL REPORT
#1

Submitted By:
SAMBIT SWARUP SATPATHY
ABHIJIT MISHRA
ARUN KUMAR
PUNIT KAR
RAKESH MISHRA
ABINASH MAHANTA
ASHIS NAIK
VIVEK KUMAR UPADHYAYA
ANIL KUMAR SAMAL
ABHISHEK KHANDELWAL

[attachment=13216]
ABSTRACT
The amateur work of us tries to bring a joint unit of air and water
cooler under one roof which can effectively reduce the cost of
manufacturing and can increase the efficiency considerably . “ Waste Chill Recovery Heat Exchanger” as the name proclaims itself the chill which would have otherwise been wasted is recovered and used up in cooling the air using a radiator . So this unit provides us with both cold water and air simultaneously as per the requirement of user .
INTRODUCTION
“Faster, mightier & smaller” is still the keyword for every invention and development. In day-to-day world we concentrate on the compactness and efficiency of every product. Keeping this in our thought we have designed and fabricated an economical and reliable unit known as “Water Cum Room Cooler”.
“Human comfort is that condition of mind, which expresses itself with the thermal environment”. In our project two rival properties of cool water and cool air are obtained. This system can be used continuously.
By using our system there is no need of going for a separate air conditioner or air cooler and water cooler. As both purposes are served by a single system, the cost is also lowered to a considerable level.
LITERATURE SURVEY
The human body works best at certain temperatures like other machines, but it cannot tolerate with range of variations. The human body maintains its thermal equilibrium by three modes of heat transfer i.e. evaporation, radiation and convection.
A human body feels comfortable when the heat produced by metabolism of human body is equal to the sum of heat dissipated to the surroundings.
The normal temperature of the human body is 37 degree centigrade or 98.6 degree Fahrenheit. But, if this level goes below 36.5 degree centigrade or 98 degree Fahrenheit and exceeds 40.5 degree centigrade or 105 degree Fahrenheit, the conditions become dangerous for human existence.
FACTORS AFFECTING HUMAN COMFORT
The important factors while designing any system of comfort are
 Effective Temperature
 Heat production & regulation in human body
 Heat and moisture losses from body
 Moisture content of air
 Quality and quantity of air
 Air motion
 Air stratification
Physiological hazards resulting from heat and extreme cold are
 Heat exhaustion
 Heat cramp
 Heat stroke
 Frost bites
 Hypothermia
 Hyperthermis
VAPOUR COMPRESSION REFRIGERATION CYCLE
The low pressure vapour in dry state is drawn from the evaporator during the suction stroke of the compressor. During compression stroke the pressure and temperature increases until the vapour temperature is greater than the temperature of condenser cooling medium
VAPOUR COMPRESSION CYCLE
CONDENSATION
When the high pressure refrigerant vapour enters the condenser heat flows from condense to cooling medium thus allowing vaporized refrigerant to return to liquid state.
EXPANSION
After condenser the liquid refrigerant is stored in the liquid receives until needed. From the receiver it passes through an expansion value where the pressure is reduced sufficiently to allow the vaporization of liquid at a low temperature of about – 10 degree centigrade.
EVAPORATION
The low pressure refrigerant vapour after expansion in the expansion valve enters the evaporator on refrigerated space where a considerable amount of heat is absorbed by it and refrigeration is furnished.
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Popular Searches: recovery of waste from ic engine ppt download, waste chill recovery system heat exchanger, project report synopsis heat exchanger, how to use a heat exchanger in ic engine, weast chill recovery heat exchanger, waste chill recovery heat exchanger project details, cc heat recovery pdf,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  Study of Recovery of Waste Heat From the Exhaust of Automotive Engine seminar surveyer 2 3,184 18-10-2014, 10:47 PM
Last Post: jaseela123d
  automatic rain operated wiper full report seminar topics 18 33,563 26-02-2014, 02:34 AM
Last Post: Guest
  ESTABLISHING A SMALL SCALE INDUSTRY FOR MANUFACTURING OF PIPE full report seminar topics 9 37,291 10-09-2013, 10:26 AM
Last Post: computer topic
  automatic temperature control of vaccum brazing furnace by using plc full report project topics 4 8,493 03-02-2013, 08:49 PM
Last Post: Guest
  NON CONVENTIONAL SOURCES OF ENERGY in Tamil Nadu full report project topics 6 8,596 23-01-2013, 02:16 PM
Last Post: seminar details
  Four-Wheel Steering System full report smart paper boy 1 3,076 14-11-2012, 11:21 AM
Last Post: seminar details
  Linbot advanced line following robot full report project topics 2 3,086 30-10-2012, 03:23 PM
Last Post: seminar details
  CRYOGENIC ENGINE IN ROCKET PROPULSION full report seminar class 1 4,072 15-10-2012, 03:29 PM
Last Post: seminar details
  DEVELOPMENT OF AN AC SYSTEM USING WASTE HEAT OF AN IC ENGINE full report project report tiger 11 14,360 10-07-2012, 10:28 AM
Last Post: seminar details
  Project Report on Heat Pipe computer girl 0 3,349 09-06-2012, 02:01 PM
Last Post: computer girl

Forum Jump: