Residual current circuit breaker
HISTORY

 World’s first protective system is developed in South Africa by Henri Rubin.
 High sensitive earth leakage protective system
 Name of that was MAGAMP.
 It was second harmonic magnetic amplifier core balance system.
 Operated at 525 V and 250 mA.
INTRODUCTION
 RCCB is the circuit breaker that senses the fault current and trips when there is a difference between amount of current in line and neutral.
 objective
 Various names of RCCB and specifications
 As per NEC various rating of RCCB
 China is only the manufacturer in the world.
 Cost ranging from 1000 to 5 lacks and more.
 Used as household appliance and in transmission line.
TYPES
 RCCBO
 RCCBS
 As per characteristic
1. Type A
 Residual sinusoidal current
 Pulsating direct current
 Independent of polarity
2. Type AC
 Only residual sinusoidal current
3. Type B
 As for type A
 Residual current up to 1000 Hz
INTERNAL MECHANISM
1. Neutral
2. Line
3. Reset button (when pressed 4 & 5 get closed)
4. Contact
5. Solenoid
6. Sense coil
7. Sense circuitry (picked up because of differential current)
8. Test button
9. Test wire
CHARACTERISTICS
 Number of poles
 Two poles for single phase
 Three poles for three phase three wire
 Four poles for three phase four wire
 Rated current
 According to maximum sustained load
 Sensitivity
 As per IEC
 High sensitivity (6-10-30 mA)
 Medium sensitivity (100-500-1000 mA)
 Low sensitivity (3-10-30 A)
LIMITATIONS
 Alone RCCB can not protect overload and short circuit. For that RCCB with overload & short circuit protection must be provided.
 Household RCCB can not protect a person who touches live and neutral contact.
 Tripping of RCCB is nuisance for earth fault.
 To avoid such condition RCCB is available in 1, 2, 3, 4 pole.
CONCLUSION
 RCCB acts like a fuse in transmission line. it senses and trips the faulty line from the rest of the healthy line.
 The cost of one RCCB is less than the cost of relay unit and circuit breaker unit so RCCB is more economical than the unit of relay and circuit breaker.
 It occupies less space.
 For different types of the faults one RCCB is required so system is became more compact.
 The TOP of RCCB is less.
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Tagged Pages: residual current circuit breaker,
Popular Searches: residual current circuit breaker, conclusion on circuit breaker, presentation on air circuit breaker, circuit breaker maintence by mo, viva question residual chlorine, residual stresses after machining, seminar topic on circuit breaker,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  Surge current protection using superconductors computer science crazy 9 10,986 16-03-2016, 12:03 AM
Last Post: computer science crazy
  Surge Current Protection Using Superconductors pradeep.srivatsa 10 10,190 16-03-2016, 12:03 AM
Last Post: computer science crazy
  Adaptive piezoelectric energy harvesting circuit for wireless remote power supply electronics seminars 3 4,547 18-02-2016, 02:18 PM
Last Post: seminar report asees
Star Surge current protection using superconductors computer science crazy 13 8,273 02-02-2015, 04:04 PM
Last Post: Guest
  Circuit Breaker Maintenance by Mobile Agent Software Technology project topics 16 13,986 23-04-2014, 08:27 PM
Last Post: Guest
Big Grin HVDC TECHNOLOGY AND SHORT CIRCUIT CONTRIBUTION OF HVDC LIGHT? seminar projects crazy 6 7,424 13-12-2012, 12:58 PM
Last Post: seminar details
  Digital Testing of High Voltage Circuit Breaker project topics 13 12,178 24-10-2012, 03:28 PM
Last Post: seminar details
  Battery charger circuit using SCR. computer girl 0 1,720 11-06-2012, 04:09 PM
Last Post: computer girl
  High-voltage direct current computer girl 0 1,319 07-06-2012, 04:58 PM
Last Post: computer girl
  High-Speed Circuit Board Signal Integrity computer girl 0 1,029 07-06-2012, 04:27 PM
Last Post: computer girl

Forum Jump: