hi am niranjana.I would like to get details on rectification of building tilt for my project work
Reply
#2
The building was founded when it was filled and within two years after construction was installed up to 800 mm and out of lead by 850 mm. Initially, balancers weighing 40,000 bricks were placed on the floor and on the first floor, and a wide grout was made. The soil was then removed from below the top of the foundation by insertion of perforated pipes and pumping water under pressure. This causes the soil to dissolve under water pressure. The soil was also collected manually. Theremoval of the earth and counter action balancing the weight gradually straightened the building until it reached verticality.


A four-storey residential building was built in 1990-92 at 60, Belgachia Road, Calcutta, about half a kilometer east of Balgachia Station, for the accommodation of Calcutta metro railway staff. It was a small building that covered a floor area of 6.8m x 16.2m with two floors on each floor. Construction finished in July 1992. Shortly after, the building began to settle. In November 1992 a vertical settlement of 1 50 mm with an adifferential settlement of 100 mm was observed. The monitoring of the settlement subsequently showed an increasing inclination of the building. In March 1993, the total settling of 450 mm was measured with a 410 mm differential. The emergency cement grout was then made / the base to stop the settlement. But this was unsuccessful. The building continued to settle differently. In March 1994, the total settlement increased to 800 mm and the building left lead by 850 mm. This resulted in a severe slope of the building and was declared unfit for occupancy.
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Tagged Pages: rectification of building tilt,
Popular Searches: azimuth and tilt of antennae, switch tilt alarm 9v, www seminar report on tilt rotor aircraft com, design and construction of mems based tilt operated, rectification for building foundation failure ppt, rectification of buiding tilt, what is the back ground ofmems based tilt operated touch free mobile phone,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  rule 27 of kerala panchayat building rules 2011 0 453 24-09-2018, 10:38 PM
Last Post: Guest
  kerala panchayat building rules malayalam pdf free download 0 681 23-09-2018, 01:39 PM
Last Post: Guest
  6th sem civil vtu alternative building materials and technologies notes download pdf 0 745 19-07-2018, 04:20 PM
Last Post: Guest
  kerala panchayat building rules 2016 malayalam pdf 0 682 12-07-2018, 10:14 AM
Last Post: Guest
  6th sem civil vtu alternative building materials and technologies notes download pdf 0 870 29-06-2018, 11:44 PM
Last Post: Guest
  kerala panchayat building rules 2013 pdf malayalam free 0 563 28-06-2018, 01:10 PM
Last Post: Guest
  kerala panchayat building rules 2016 malayalam pdf 1 660 03-05-2018, 12:38 PM
Last Post: Guest
  kmbr building rules malayalam version 0 437 03-05-2018, 12:36 PM
Last Post: Guest
  kerala panchayat building rules 2016 malayalam pdf 0 375 19-03-2018, 10:38 PM
Last Post: Guest
  solar passive building seminar report pdf 0 447 26-02-2018, 07:31 PM
Last Post: Guest

Forum Jump: