Digital Testing of High Voltage Circuit Breaker ppt
#1

INTROUCTION to Digital Testing of High Voltage Circuit Breaker

With the advancement of power system, the lines and other equipment operate at very high voltages and carry large currents. High-voltage circuit breakers play an important role in transmission and distribution systems. A circuit breaker can make or break a circuit, either manually or automatically under all conditions viz. no-load, full-load and short-circuit conditions. The American National Standard Institute (ANSI) defines circuit breaker as: "A mechanical switching device capable of making, carrying and breaking currents under normal circuit conditions and also making, carrying for a specified time, and breaking currents under specified abnormal circuit conditions such as those of short circuit". A circuit breaker is usually intended to operate infrequently, although some types are suitable for frequent operation.

ESSENTIAL QUALITIES OF HV CIRCUIT BREAKER

High-voltage circuit breaker play an important role in transmission and distribution systems. They must clear faults and isolate faulted sections rapidly and reliably. In-short they must possess the following qualities.

" In closed position they are good conductors.
" In open position they are excellent insulators.
" They can close a shorted circuit quickly and safely without unacceptable contact erosion.
" They can interrupt a rated short-circuit current or lower current quickly without generating an abnormal voltage.

The only physical mechanism that can change in a short period of time from a conducting to insulating state at a certain voltage is the arc.

HISTORY

The first circuit breaker was developed by J.N. Kelman in 1901. It was the predecessor of the oil circuit breaker and capable of interrupting a short circuit current of 200 to 300 Ampere in a 40KV system. The circuit breaker was made up of two wooden barrels containing a mixture of oil and water in which the contacts were immersed. Since then the circuit breaker design has undergone a remarkable development. Now a days one pole of circuit breaker is capable of interrupting 63 KA in a 550 KV network with SF6 gas as the arc quenching medium.

THE NEED FOR TESTING

Almost all people have experienced the effects of protective devices operating properly. When an overload or a short circuit occurs in the home, the usual result is a blown fuse or a tripped circuit breaker. Fortunately few have the misfortune to see the results of a defective device, which may include burned wiring, fires, explosions, and electrical shock.

It is often assumed that the fuses and circuit breakers in the home or industry are infallible, and will operate safely when called upon to do so ten, twenty, or more years after their installation. In the case of fuses, this may be a safe assumption, because a defective fuse usually blows too quickly, causing premature opening of the circuit, and forcing replacement of the faulty component. Circuit breakers, however, are mechanical devices, which are subject to deterioration due to wear, corrosion and environmental contamination, any of which could cause the device to remain closed during a fault condition. At the very least, the specified time delay may have shifted so much that proper protection is no longer afforded to devices on the circuit, or improper coordination causes a main circuit breaker or fuse to open in an inconvenient location.
Reply
#2
hai dis is bharani pls send me the ppt of digital testing of high volltage circuit breaker
Reply
#3

you can read more on 'digital testing of high voltage circuit breakers' from the following thread.

http://studentbank.in/report-digital-tes...it-breaker
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Popular Searches: digital testing of high voltage circuit breaker ppt of slides, testing of high voltage circuit breaker ppt, ppt of digital testing of high voltage circuit breaker, digital testing of high voltage circuit breakers slides, circuit breaker ppt images, advantage of digital testing of high voltage circuit breaker in wikipedia, penetrant testing ppt,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  digital jewellery abstract in ieee format 4 5,442 11-07-2018, 09:00 PM
Last Post: farsanakuttickal
  circuit diagram of smoke detector using at89s52 2 13,799 29-06-2018, 01:05 PM
Last Post: Guest
  50 scenarios on gmail in integration testing 2 2,603 30-04-2018, 11:39 AM
Last Post: Guest
  seminar report on 3d solar cells ppt paper presentation ppt seminars report on 3d solar cells ppt paper presentation ppt 5 43,084 15-04-2018, 08:39 AM
Last Post: Guest
  circuit diagram dc motor speed and direction control over gsm mobile modem pdf 2 15,074 19-03-2018, 10:57 AM
Last Post: Guest
  water level indicator circuit using 8085 microprocessor ppt 3 13,686 12-02-2018, 04:33 PM
Last Post: dhanabhagya
  edge avoider robot using atmega8 circuit 3 12,431 20-01-2018, 10:34 AM
Last Post: dhanabhagya
Smile physics investigatory projects for class 12 cbse to set up a common base transistor circuit and to study its input and o 3 25,141 20-12-2017, 09:44 AM
Last Post: jaseela123d
  digital access keypad sf 6662 4 5,367 15-11-2017, 10:38 AM
Last Post: jaseela123d
  matlab code for speed breaker detection 1 1,295 27-10-2017, 10:22 AM
Last Post: Guest

Forum Jump: