panic alarm ppt
#1

hi im swathi i need panic alarm ppt for my projects
Reply
#2
A panic alarm is an electronic device designed to assist in alerting somebody in emergency situations where a threat to persons or property exists.

A panic alarm is frequently but not always controlled by a concealed panic alarm button. These buttons can be connected to a monitoring center or locally via a silent alarm or an audible bell/siren. The alarm can be used to request emergency assistance from local security, police or emergency services. Some systems can also activate closed-circuit television to record or assess the event.[1]

Many panic alarm buttons lock on when pressed, and require a key to reset them.

Introduction to Panic Alarms
Purpose

The purpose of a panic alarm is to allow a person under duress to quickly and silently call for help in the event of an emergency. Panic alarms are also called "duress alarms", "hold-up alarms", or "panic buttons".

Panic alarms are used when it may be unsafe or uncomfortable to call for help in other ways. For example, if a belligerent person is standing in your lobby, it may be unwise to further escalate the situation by picking up a phone to call for assistance. A panic alarm can provide a quick and convenient way to summon help without drawing attention.

Silva Consultants feels that almost every business can benefit from the use of panic alarms. Places where panic alarms may be particularly beneficial include:
Receptionist's desks in building lobbies.
Security stations and checkpoints.
Shipping/receiving areas.
Customer service counters.
Check-out counters and cashier's stations.
Rooms where cash or other valuables are received, processed, or stored.
Interview rooms in Human Resources department.
Executive office suites.
Places where confrontations with the public are likely to occur.
Components of a Panic Alarm System
Panic alarms consist of two basic components:

Panic Button

The panic button is the device that the person activates when he or she needs help. There are many styles of panic buttons available. These can have a single pushbutton, two pushbuttons that must be pressed simultaneously, devices that must be squeezed, and devices that are activated by a foot or knee. There are also devices that can be covertly activated when cash or a product is removed at the request of a robber. Most panic buttons are specifically designed to resist accidental activation.

Panic buttons are normally installed in a location where they can easily be reached, yet out of view of the casual observer. In many cases, panic buttons are installed on the underside of a desk or counter-top.

Panic buttons can be the wired type or wireless type. Wired panic buttons are connected using cabling. Wired panic buttons are very reliable, but it can sometimes be difficult and costly to get cable to each panic button location.

Wireless panic buttons use a short-range radio transmitter, similar to that used with a garage door opener. Wireless panic buttons are easy to install and can be placed just about anywhere. Wireless panic buttons can also be carried around on the premises by employees if desired. Wireless panic buttons require batteries and need to be tested frequently to assure that they are operating properly.

Communications System

The communications system is the method that is used to summon help when a panic button is pressed. The type of communications system used depends largely on the resources available at the facility where the panic alarm is being installed and the level of security threat.

Types of communications systems used can include:

Communications to an off-site alarm monitoring center:

This method would typically be used at facilities that do not have an on-site security staff, such as at a small business. The panic buttons would be connected to an alarm control panel which sends a signal to the monitoring center when a panic button is pressed. The alarm monitoring center would then call the police or other appropriate people to respond to the site.

Communications to security control center:

Most large companies have some type of centralized security monitoring and control center, either on-site, or at a central location somewhere within their organization. When this type of resource exists, panic buttons are typically monitored at the control center. Most often, panic buttons are connected to the organization's access control and security management system, which transmits the alarm to the control center.

When a panic button is pressed, it sounds an alarm in the security control center. The center would then dispatch local security officers and/or the police to respond to the site.

Communications to non-security personnel:

Some organizations that do not have on-site security choose to notify non-security personnel when a panic button is pressed. Often, the organization will form a "response team" consisting of employees from multiple departments (Facilities, HR, etc.) and ask that these employees respond when a panic button is pressed.

There are various systems that can be used to notify the response team when a panic button has been pressed. These include can include overhead paging systems and devices that send voice messages, text messages, or email messages directly to smartphones.

Tips for Successfully Using Panic Alarms

Panic alarms are worthless unless people know how to use them. Provide frequent training and make employees practice using panic buttons, particularly at positions where there is high employee turnover.
When possible, provide a video surveillance camera that views each area where a panic button is installed. The panic alarm system should be interfaced to the video surveillance system to provide real-time recording when a panic button has been pressed. At facilities that have a security control center, the video surveillance system should automatically display the appropriate cameras at the control center whenever a panic button has been activated. This allows the center to assess the situation in order to send the proper response.
Facilities that use a response team to respond to panic alarms should have some method to assess the situation before personnel enter the scene. Cameras that view panic button locations should be remotely viewable by response team members. This can be done using a computer on the network that has video viewing software, or by providing one or more dedicated video monitors.
In some locations, different types of responses may be needed to handle different types of situations. For example, a drunk person in the lobby poses a different threat than an armed robber, yet employees may wish to have a method for discretely summoning help in either case. To handle this, it is possible to install what we call a "two-state" panic button. This button can be programmed so that two types of signals can be sent, one for true emergencies, and one for when help is needed but the situation doesn't require an emergency response.
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Popular Searches: buttons in bulk, advantages of panic alarm using 555 timer, 6 phases of a project panic, wi5 alarms, panic alarm using 555 timer ppt, ppt of panic alarm circuit pdf, panic alarm circuit ppt pdf download,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  Over Speed Alarm Indicators of Electrical Motor with Digital RPM Indicator 0 261 25-07-2023, 05:33 AM
Last Post:
  Earthquake detection alert alarm for people security ppt 0 870 06-01-2019, 09:29 AM
Last Post:
  Earthquake detection alert alarm for people security 0 790 06-01-2019, 09:25 AM
Last Post:
  fire alarm project for class xii pdf 0 1,187 31-10-2018, 08:37 PM
Last Post: Guest
  advantages and disadvantages mains failure alarm circuit in pdf 0 784 01-10-2018, 11:48 PM
Last Post: Guest
Tongue engine overheat alarm pdf 0 540 04-08-2018, 08:32 AM
Last Post: Guest
  literature review of automatic brake failure indicator and engine overheating alarm 0 706 09-05-2018, 05:06 PM
Last Post: Guest
  disadvantages of water alarm 0 382 05-05-2018, 11:20 PM
Last Post: Guest
  fire alarm ppt using 555 ic Thein Hla Maw 0 572 26-04-2018, 03:05 PM
Last Post: Thein Hla Maw
  panic alarm mini project report pdf or ppt 0 576 02-04-2018, 06:26 PM
Last Post: Guest

Forum Jump: