some information here letest ie rule seminar

Abstract of IE Rules

Abstract of Indian Electricity Rules:

1) Cut-out on consumer’s premises:

The supplier shall provide a suitable cut-out in each conductor of every service-line other than an earthed or earthed neutral conductor or the earthed external conductor of a concentric cable within a consumer’s premises, in an accessible position. Such cut-out shall be contained within an adequately enclosed fireproof receptacle.
Where more than one consumer is supplied through a common service-line, each such consumer shall be provided with an independent cut-out at the point of junction to the common service
Every electric supply line other than the earth or earthed neutral conductor of any system or the earthed external conductor of a concentric cable shall be protected by a suitable cut-out by its owner
No cut-out, page link or switch other than a linked switch arranged to operate simultaneously on the earthed or earthed neutral conductor and live conductors shall be inserted or remain inserted in any earthed or earthed neutral conductor of a two wire-system or in any earthed or earthed neutral conductor of a multi-wire system or in any conductor connected thereto with the following exceptionsSada) A page link for testing purposes, or (b) A switch for use in controlling a generator or transformer.
2) Danger Notices:
The owner of every medium, high and extra-high voltage installation shall affix permanently in a conspicuous position a danger notice in Hindi or English and the local language of the district, with a sign of skull and Bones on
(a) Every motor, generator, transformer and other electrical plant and equipment together with apparatus used for controlling or regulating the same;
(b) All supports of high and extra-high voltage overhead lines which can be easily climb-upon without the aid of ladder or special appliances.
3) Cables :
Flexible cables shall not be used for portable or transportable motors, generators, transformer rectifiers, electric drills, electric sprayers, welding sets or any other portable or transportable apparatus unless they are heavily insulated and adequately protected from mechanical injury.
Where the protection is by means of metallic covering, the covering shall be in metallic connection with the frame of any such apparatus and earth.
The cables shall be three core type and four-core type for portable and transportable apparatus working on single phase and three phases supply respectively and the wire meant to be used for ground connection shall be easily Identifiable
Where A.C. and D.C. circuits are installed on the same support they shall be so arranged and protected that they shall not come into contact with each other when live.

Transformer:

Where transformer or transformers are used, suitable provision shall be made, either by connecting with earth a point of the circuit at the lower voltage or otherwise, to guard against danger by reason of the said circuit becoming Accidentally charged above its normal voltage by leakage from or contact with the circuit at the higher voltage
A sub-station or a switch station with apparatus having more than 2000 litres of oil shall not be located in the basement where proper oil draining arrangement cannot be provided.
Where a sub-station or a switch station with apparatus having more than 2000 litres of oil is installed, whether indoor or out-doors, the following measures shall be taken, namely: –
The baffle walls 4[of 4 hour fire rating] shall be provided between the apparatus in the following cases: –
(1) Single phase banks in the switch-yards of generating stations and substations;
(2) On the consumer premises;
(3) Where adequate clearance between the units is not available.
Provisions shall be made for suitable oil soakpit and where use of more than 9000 litres of oil in any one oil tank, receptacle or chamber is involved, provision shall be made for the draining away or removal of any oil which may leak or escape from the tanks receptacles or chambers containing the same.
The transformer shall be protected by an automatic high velocity water spray system or by carbon dioxide or BCF (Bromo chlorodi feuromethane) or BTM (Bromo tri fluromethane) fixed installation system; and
Oil filled transformers installed indoors shall not be on any floor above the ground or below the first basement.
Isolators and the corresponding earthing switches shall be interlocked so that no earthing switch can be closed unless and until the corresponding isolator is in open position.
When two or more transformers are operated in parallel, the system shall be so arranged as to trip the secondary breaker of a transformer in case the primary breaker of that transformer trips.
Where two or more generators operate in parallel and neutral switching is adopted, inter-lock shall be provided to ensure that generator breaker cannot be closed unless one of the neutrals is connected to the earthing system.
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Popular Searches: letest developments in mechanical engg 2011 2012, letest ie rule seminar, selipalan bandist mahiti letest, current and letest trades in ic engine, letest gear box in automobil e, letest seminar topics for plastic and polymer engineering, letest parlour course in hindi,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
Wink seminar report on pavement design using geotextiles 4 1,297 18-05-2017, 11:08 AM
Last Post: Umeshyuvi
  seminar topics in plant science and biotechnology 3 1,580 14-02-2017, 11:03 AM
Last Post: ijasti
  seminar report regenerative shock absorber pdf 2 952 01-10-2016, 03:40 PM
Last Post: Guest
  seminar report on underwater construction pdf 3 1,314 17-08-2016, 01:43 PM
Last Post: anasek
  sample impression message after seminar 2 835 28-07-2016, 04:19 PM
Last Post: jaseela123d
  sample impression message after seminar 1 1,372 23-07-2016, 10:16 AM
Last Post: jaseela123d
  sanskrit quotes for vote of thanks related to seminar 1 1,830 21-07-2016, 04:40 PM
Last Post: jaseela123d
  closing impression message for seminar 2 915 21-07-2016, 04:36 PM
Last Post: jaseela123d
  seminar topics on aquatic microbiology 2 792 21-07-2016, 02:37 PM
Last Post: jaseela123d
  seminar topics in aquatic microbiology 2 600 21-07-2016, 02:36 PM
Last Post: jaseela123d

Forum Jump: