Ion Chamber Dosimetry: Accuracy in Small X-Ray Field Measurements
#1

Modern radiation therapy techniques, such as stereotactic radiotherapy and tomotherapy, deliver the total treatment dose to the patient using many small fields. This helps to construct a dose distribution which delivers a high dose to the tumour, while minimizing the dose to normal tissue. When considering a single small field, the dose resulting from that small field is usually reported as a relative dose factor (RDF). The RDF is the percentage of dose in a small field as compared to a large reference field. Task group report #51 from the American Association of Physicists in Medicine (AAPM) provides the protocol according to which absolute dose measurements using an ion chamber must be taken, all with respect to measurements at a reference point in a large reference field. In the case of RDF measurements several assumptions are made which allows for the simplification of the TG-51 protocol, but attention is not necessarily paid to the fact that the conditions in a large reference field differ considerably from those ina small field. In this study we have used experimental measurements with plane-parallel ion chambers and theoretical simulations (Monte Carlo BEAMnrc code) to investigate the validity of the assumptions made in the determination of RDFs for small fields. Four custom-made plane parallel ion chambers, as well as other common high resolution radiation dosimeters, were used to measure the dose response in circular 6MV stereotactic radiotherapy fields. BEAMnrc was then used to simulate the experimental conditions and determine the validity of the assumptions mentioned previously. The assumptions were determined to be invalid for use in small radiation fields. Corrections


were calculated from Monte Carlo results and applied to the experimental measurements. Care needs to be taken when applying existing protocols to non-reference conditions
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Popular Searches: aerated grit chamber rotational velocity of wastewater fps, ion exchange seminar, ppt on combustion chamber in si engine, m type combustion chamber pdf, gentamicin dose, grit chamber design scribd, combustion chamber volume,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  Nanotechnology In Medical field seminar class 2 5,316 08-02-2012, 11:08 AM
Last Post: seminar addict
  Growth pattern of Small Scale Units of Women Entrepreneurs: super 0 4,160 14-06-2009, 09:25 AM
Last Post: super

Forum Jump: