power factor correction using 8051 microcontroller wiki
#1

i need thesis on automatic powerfactor correction using micro controller.
Reply
#2

This is a Electrical project work on Automatic power factor correction using micro-controller 8051 and this power factor correction device reads power factor from line voltage and line current by determining the delay in the arrival of the current signal with respect to voltage signal from the function generator with high accuracy by using an internal timer. This device is a very useful device for improving efficient transmission of active power. If the consumer connect inductive load, then the power factor lags, when the power factor goes below 0.97(lag) then the Electric supply company charge penalty to the consumer. You can also Subscribe to FINAL YEAR PROJECT'S by Email for more such projects and seminar.

Automatic power factor correction techniques can be applied to the industries, power systems and also house holds to make them stable and due to that the system becomes stable and efficiency of the system as well as the apparatus increases. The use of microcontroller reduces the costs. Automatic Power factor correction device reads the power factor from line voltage and line current, calculating the compensation requirement switch on different capacitor banks. This report includes complete power factor theory, circuit diagram, block diagram, microcontroller programming source code. Use it for your reference and study work.

The thirst for new sources of energy is unquenchable, but we seldom realize that we are wasting a part of the electrical energy every day due to the lagging power factor in the inductive loads we use. Hence there is an urgent need to avoid this wastage of energy.

Before getting into the details of Power factor correction, lets just brush our knowledge about the term “power factor”. In simple words power factor basically states how far the energy provided has been utilized. The maximum value of power factor is unity. So closer the value of P.F to unity, better is the utility of energy or lesser is the wastage. In electrical terms Power factor is basically defined as the ratio of the active power to reactive power or it is the phase difference between voltage and current. Active power performs useful work while Reactive power does no useful work but is used for developing the magnetic field required by the device.

Most of the devices we use have power factor less than unity. Hence there is a requirement to bring this power factor close to unity. Here we are presenting a prototype for automatic power factor correction using PIC Microcontroller.
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Popular Searches: power factor correction using 8051 microcontroller program coding, power factor correction using shunt and series filters wiki, world top 10 military power wiki, microcontroller for power factor correction in power systems pdf, power factor correction using microcontroller 8051 and capacitor banks pdf, automatic power factor correction using 8051 microcontroller seminar, automatic power factor correction circuit diagram using mc 8051,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  power plant instrumentation by krishnaswamy pdf free download 3 24,540 10-02-2019, 07:00 PM
Last Post:
  jobs in kanti thermal power plant muzaffarpur 3 8,974 17-01-2018, 01:14 PM
Last Post: [email protected]
  source code for task scheduling using genetic algorithm using java 2 8,714 11-04-2017, 08:31 PM
Last Post: Guest
  literature review of gearless power transmission system 2 1,754 23-09-2016, 09:07 AM
Last Post: Guest
  source code in c for automatic irrigation system using 8051 2 997 03-08-2016, 10:53 AM
Last Post: seminar report asees
  online correction of samagra id 2 552 23-07-2016, 03:22 PM
Last Post: jaseela123d
  online correction of samagra id 1 1,048 23-07-2016, 03:02 PM
Last Post: jaseela123d
  pelagia research library journals impact factor 3 673 23-07-2016, 02:50 PM
Last Post: jaseela123d
Wink online correction of samagra id 1 459 22-07-2016, 04:19 PM
Last Post: dhanabhagya
  online correction of samagra id 1 872 22-07-2016, 03:05 PM
Last Post: jaseela123d

Forum Jump: