how to take reading in genus digital meter
#1

Iwant to know the consumptiòion electricityof myhousebysinglephase electric genus meter insalled in my house byboard.
Reply
#2
how to take reading in genus digital meter

Meter Reading Instruments
Genus SamvaadTM is a microprocessor based high speed Hand Held Unit for Data Downloading from Electricity Meter both rometly & locally. The device is available with different communicating topologies i.e. Optical Communication (RS-232), Infra Red, IrDA, LPRF. Interal memory storage can store all Data, Load Survey & other Tamper/Event of Meter for uploading at base station computer software Genus URJATM for Meter data analysis. Being rechargeable battery operated device, it can communicate with local computer/laptop using RS-232 (D-9pin) port.

Three Phase Meters
A 3 phase, 4 wire, class 1, whole current (10-100A), Time of Use, static Electricity meter conforming to IEC-62053-21/23 and IEC-62054. Dual processor Environment with a processor dedicated to metrology & computation and the other for communication & calculations. Designed for MTBF better than 250 Years .
A dual processor design achieves the very high BAUD rate (IEC-62056-21) ,9.6Kbps resulting in a quick downloading of data and at the same time permitting advance communication with PSTN , PLC , GPRS, LOW Power Radio MODEMs
6 separate S? ADCs for accurate measurement , thus alleviating the need for filtering algorithms for ADC multiplexing errors.
4 Quadrant Metering, with active/reactive, import/export
Time of use metering, Up to 12 configurable TOU slots & 12 tariffs, 3 types of days, 4 seasons, daylight saving in accordance with IEC 62054.
TOU function is supported by EPSON’s factory calibrated RTC with an accuracy of up to 3 minutes per year. RTC developed on GENUS feedback has a 32.768KHz internal crystal with a stability of better than ±5 PPM
Detects all types of tampers, frauds and anomalies & prevents energy pilferage
Active and Reactive/Apparent Pulse outputs
85 days Load profile with kWh, kVAh, kVArh Lag, kVArh Lead, average voltages & average currents, Average frequency for the integration period for integration period of 30 minutes.
12 months history of billing parameters
Configurable parameters viz. TOU tables, Maximum Demand integration period, persistence time for tamper registration and restoration, apparent calculation method
Supporting Software. The product is shipped with an efficient meter reading program and a highly user friendly base station software URJA for METER data processing
Battery backup for meter reading in the event of power outage.
Immune to very strong magnetic and radiated/conducted electromagnetic disturbance

Single Phase Meters
1 phase, 2 wire, class 1, whole current, Tamper proof, Time of Use, Static Electricity meter conforming to IEC-62053-21/23, IEC-62054 and IS 13779. Designed for MTBF 200 years.
24 bit S? ADCs for accurate measurement.
Measurescurrent in both the elements (Phase & Neutral), makes meter tamper proof.
High Energy resolution(4 decimal), reduces energy loss due to power outage.
Extra ordinary Anti tamper features Current reversal, Earth tampers Pase/Neutral cut, Neutral Loop, Pure/Chopped DC injection in Phase/Neural circuit.
Phase/Neutral cut tamper.
Low Starting Current– 1AAccuracy –2.5A to 60A.
Extended immunity to HF ,Tested up to 5W RF power Frequency range ( 30—370 MHz).
Measures Active energy, Apparent energy , Maximum Demand kW, Maximum demand kVA ,True rms Voltage , True rms Phase Current, True rms Neutral Current, Instantaneous signed Power Factor ,Instantaneous Frequency, Instantaneous Load.
Time of use metering, Up to 6 configurable TOU slots & 6 tariffs, 3 types of days, 4 seasons, daylight saving in accordance with IEC 62054.
Optical portHardware compatible to IEC 62056 –21,Withvery high BAUD rate9.6Kbpsresulting in a quick downloading of data.
TOU function is supported by EPSON’s factory calibrated RTC with an accuracy of up to 3 minutes per year.RTC developed on GENUS feedback has a 32.768KHz internal crystal with a stability of better than ±5 PPM.
Active Pulse outputs & Visual tamper indications.
Store 35 days Load profile withkWh, average voltage & average current,for the integration period for integration period of 30 minutes.
6 months history of billing parameters.
Supporting Software. The product is shipped with an efficient meter reading program and a highly user friendly base station software URJA for METER data processing.
Battery backup for meter reading in the event of power outage.

To get full information or details of how to take reading in genus digital meter please have a look on the pages

http://seminarsprojects.in/showthread.ph...&tid=79207

if you again feel trouble on how to take reading in genus digital meter please reply in that page and ask specific fields in how to take reading in genus digital meter
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Popular Searches: epson ex 21, how to take reading in genus digital meter, naisargic urja, es pase informed, genus computer meater, how to see digital current meter reading tneb, digital electric meter reading,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  digital jewellery abstract in ieee format 4 5,412 11-07-2018, 09:00 PM
Last Post: farsanakuttickal
Smile how to take santoor soap dealership details pdf 3 2,767 26-05-2018, 12:01 AM
Last Post: Nehal Shaik
  digital access keypad sf 6662 4 5,344 15-11-2017, 10:38 AM
Last Post: jaseela123d
  matlab code for digital watermarking using dct and dwt 5 4,409 19-05-2017, 02:59 PM
Last Post: jaseela123d
  digital code lock using ic 4013 1 750 11-04-2017, 03:19 PM
Last Post: jaseela123d
  source code for digital signature with rsa encryption algorithm 1 841 07-04-2017, 12:45 PM
Last Post: jaseela123d
  ppt for microcontroller based ultrasonic distance meter 1 904 05-04-2017, 05:00 PM
Last Post: jaseela123d
  a web based image transmission system using digital watermark pdf 2 919 04-04-2017, 04:45 PM
Last Post: jaseela123d
Exclamation digital electric meter jammer for house 1 1,254 04-04-2017, 01:03 PM
Last Post: jaseela123d
  genus meter 03b how to check reading 1 931 30-03-2017, 04:51 PM
Last Post: jaseela123d

Forum Jump: