In earthquake engineering, vibration control is a set of technical means aimed to mitigate seismic impacts in building and non-building structures.
All seismic vibration control devices may be classified as passive, active or hybrid where:

Base isolator being tested at the UCSD Caltrans-SRMD facility
passive control devices have no feedback capability between them, structural elements and the ground;
active control devices incorporate real-time recording instrumentation on the ground integrated with earthquake input processing equipment and actuators within the structure;
hybrid control devices have combined features of active and passive control systems.
When ground seismic waves reach up and start to penetrate a base of a building, their energy flow density, due to reflections, reduces dramatically: usually, up to 90%. However, the remaining portions of the incident waves during a major earthquake still bear a huge devastating potential.
After the seismic waves enter a superstructure, there is a number of ways to control them in order to sooth their damaging effect and improve the building's seismic performance, for instance:
to dissipate the wave energy inside a superstructure with properly engineered dampers;
to disperse the wave energy between a wider range of frequencies;
to absorb the resonant portions of the whole wave frequencies band with the help of so-called mass dampers

Base-isolated San Francisco City Hall after seismic retrofit
Devices of the last kind, abbreviated correspondingly as TMD for the tuned (passive), as AMD for the active, and as HMD for the hybrid mass dampers, have been studied and installed in high-rise buildings, predominantly in Japan, for a quarter of a century .
However, there is quite another approach: partial suppression of the seismic energy flow into the superstructure known as seismic or base isolation which has been implemented in a number of historical buildings all over the world and remains in the focus of earthquake engineering research for years.
For this, some pads are inserted into all major load-carrying elements in the base of the building which should substantially decouple a superstructure from its substructure resting on a shaking ground. It also requires creating a rigidity diaphragm and a moat around the building, as well as making provisions against overturning and P-delta effect.
In refineries or plants snubbers are often used for vibration control. Snubbers come in two different variations: hydraulic snubber and a mechanical snubber.
Hydraulic snubbers are used on piping systems when restrained thermal movement is allowed.
Mechanical snubbers operate on the standards of restricting acceleration of any pipe movements to a threshold of 0.2 g's, which is the maximum acceleration that the snubber will permit the piping to see.[
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Popular Searches: earthquake vibration control using modified frame shear wall ppt, effect of earthquake on shear wall, earthquake vibration alarm ppt, about earthquacke vibration controll using modified frame, http seminarprojects org t earthquake vibration control using modified frame shear wall pdf, earthquake vibration alarm circuit, earthquake resisting shear wall construction,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  code for avr atmega16 with gsm 900 to control light 2 965 24-01-2019, 12:03 PM
Last Post:
  Earthquake detection alert alarm for people security ppt 0 865 06-01-2019, 09:29 AM
Last Post:
  Earthquake detection alert alarm for people security 0 784 06-01-2019, 09:25 AM
Last Post:
  adaptive cruise control seminar report pdf for download 0 1,139 02-10-2018, 11:48 AM
Last Post: Guest
  download journal papers on new techniques of erosion control in hilly roads 0 681 12-08-2018, 11:12 PM
Last Post: Guest
  ppt on fire behaviour of steel penetrating concrete wall 0 573 09-08-2018, 07:45 PM
Last Post: Guest
  ppt on automatic vehicle speed control by using rfid 0 662 03-08-2018, 09:24 PM
Last Post: Guest
  traffic light control system using 8086 code 0 830 12-07-2018, 09:46 AM
Last Post: Guest
  seminar report shear walls 0 469 01-05-2018, 12:18 PM
Last Post: Guest
  free ppt of management control system of maruti suzuki 0 703 21-04-2018, 02:13 AM
Last Post: Guest

Forum Jump: