dc motor braking ppt
#1

I wanna get ppt on electrical bracking on tracking system
Reply
#2

A running motor may be brought to rest quickly by either mechanical braking or electrical braking. The mechanical braking is applied by means of mechanical break shoes. Hence the smoothness of mechanical braking is dependent on the surface and physical condition of brakes. Smooth braking of a motor can be achieved by electric braking.

Electric Braking
The electric braking of a DC motor is of three types, (i) Rheostatic or dynamic braking, (ii) Plugging or reverse current braking and (iii) Regenerative beaking.

(i) Rheostatic or dynamic braking:
In case of DC shunt motors, armature is disconnected from the supply and a rheostat (variable resistor) is connected across it. The field winding is left connected across the supply. Obviously, now armature is driven by the inertia and hence machine starts acting as a generator. Thus the machine will now feed the current to the connected rheostat and heat will dissipate at the rate of I2R. Braking effect is controlled by varying the resistance connected across the armature.
In case of DC series motor, motor is disconnected from the supply and field connections are reversed and a rheostat is connected in series. The field connections are reversed to make sure that the current through field winding will flow in the same direction as before.

(ii) Plugging or Reverse current braking:
In this method, armature connections are reversed and hence motor tends to run in opposite direction. Due to reversal of the armature terminals, applied voltage V and back emf Eb starts acting in the same direction and hence the total armature current exceeds. To limit this armature current a variable resistor is connected across the armature. This is similar for both series and shunt wound methods.
Plugging gives greater braking torque as compared to rheostatic braking. This method is generally used in controlling elevators, machine tools, printing presses etc.

(iii) Regenerative braking:
Regenerative braking is used where, load on the motor has very high inertia (e.g in electric trains). When applied voltage to the motor is reduced to less than back emf Eb, obviously armature current Ia will get reversed, and hence armature torque is reversed. Thus speed falls. As generated emf is greater than applied voltage (machine is acting as a DC generator), power will be returned to the line, this action is called as regeneration. Speed keeps falling, back emf Eb also falls until it becomes lower than applied voltage and direction of armature current again becomes opposite to Eb.
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Popular Searches: automatic braking system for motor veh, dc injection braking to ac motor full ppt, induction motor dynamic braking, epm bracking,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  Over Speed Alarm Indicators of Electrical Motor with Digital RPM Indicator 0 265 25-07-2023, 05:33 AM
Last Post:
  complete project report on regenerative braking system pdf 0 512 09-07-2018, 06:33 AM
Last Post: Guest
  motor winding books pdf free download in hindi 0 1,710 30-04-2018, 06:32 PM
Last Post: Guest
  future scope of four quadrant dc motor speed control with microcontroller 0 753 20-04-2018, 05:52 PM
Last Post: Guest
  vacuum braking system literature review 0 413 05-04-2018, 09:59 PM
Last Post: Guest
  wiper motor working principle ppt 0 478 02-04-2018, 03:07 PM
Last Post: Guest
  motor winding book in hindi pdf 0 1,969 11-03-2018, 01:31 PM
Last Post: Guest
  speed control of dc motor by dtmf using ppt 0 383 09-03-2018, 11:22 AM
Last Post: Guest
  ppts on torque control on bldc motor 2 562 25-01-2018, 03:21 PM
Last Post: Guest
  literature review in pedal and motor operated hacksaw 2 550 22-01-2018, 10:57 AM
Last Post: dhanabhagya

Forum Jump: