Reply
#2
Shock absorbers and their performance during the earthquake. In addition, they have investigated the world's tall buildings and have studied a satisfactory level of damper performance. And the results show that not only shock absorbers have acceptable seismic behavior against lateral forces such as wind and earthquakes. However, it has reduced the limitations of building multi-storey buildings. A tuned dampener, also known as a harmonic damper, is a device mounted on structures to reduce the amplitude of mechanical vibrations. Its application can prevent discomfort, damage or absolute structural failure. They are frequently used in power transmission, automobiles and buildings. The seismic insulation of a structure reduces the transfer to the earthquake movement structure of the earthquake. 

Seismic insulation is typically obtained by a damping system that acts as a base insulation between the structure and the floor. Such damping systems are designed to protect structural integrity and prevent damage and injury to occupants by reducing seismic forces and deformations in the structure, Housner et al. (1997). Several types of basic insulation systems have been proposed and investigated; See p. (Skinner et al., 1993, Chopra 1995). The number of projects with these systems is increasing in different places around the world and basic insulation systems have proven their value through many earthquakes. Friction dampers are often an essential component of these basic insulation systems because they represent a high potential for energy dissipation at low cost and are easy to install and maintain. Several friction devices have been tested experimentally, see (Aiken and Kelly 1990, Constantinou, 1991), and some of them have been implemented in buildings all over the world. Viscoelastic dampers are also often used in base insulation systems, see p. Kelly (1999). The present work refers to the development of a new viscoelastic friction damper of low cost and its application in a damping system for the base insulation of a structure. The shock absorber can be manufactured and installed easily in a short time. The friction version of the shock absorber has been installed in several buildings in Japan. Next, a computational model for the mechanical behavior of the damper is established. This model is combined with another computational model of the damping system and the structure charged by an earthquake. Next, this model is used to determine the essential amounts of structural design depending on the intensity of the earthquake. Several models and applications of new damping systems will also be presented.
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Popular Searches: youtube r kelly, seminar topics on dampers, dampers in seismic ppt, dampers in buildings ppt, application of dampers in buildings ppt, ppt on dampers in tall buildings, viscous dampers ppt,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  seminar report on 3d solar cells ppt paper presentation ppt seminars report on 3d solar cells ppt paper presentation ppt 5 42,609 15-04-2018, 08:39 AM
Last Post: Guest
  passive solar buildings seminars ppt presentation 9 15,107 17-11-2017, 09:56 AM
Last Post: jaseela123d
  fayol s principles of management used in amul 10 9,989 03-07-2017, 10:26 AM
Last Post: jaseela123d
  fayol s principles of management used in amul 2 2,298 03-06-2017, 10:12 PM
Last Post: Guest
  what os are used in e ball 1 696 15-04-2017, 01:18 PM
Last Post: jaseela123d
  civil engineering ppt topics on green buildings 1 753 12-04-2017, 01:22 PM
Last Post: jaseela123d
  what kind of bionanomaterials are used for water treatment 1 765 05-04-2017, 03:25 PM
Last Post: jaseela123d
  impact of lightning on buildings and its remedial measures ppt 1 801 28-03-2017, 12:36 PM
Last Post: jaseela123d
  fayol s principle used in vodafone company 1 1,297 27-03-2017, 12:24 PM
Last Post: jaseela123d
  training methods used in hcl company 1 871 23-03-2017, 04:41 PM
Last Post: jaseela123d

Forum Jump: