Cryo Tracker full report
#1

[attachment=2058]
Commercial Applications


Cryogenic storage and transport tanks
Home oxygen vessels
Medevac helicopter and military field hospital oxygen-generating systems
Automobiles running on liquid hydrogen or liqufied natural gas
Reply
#2
Cryo-Tracker Level, Temperature, and Mass Gauging Fluid Sensors
[attachment=8147]


Behavior of Sub-cooled Propellants in Room Temp.
Fig: Liquid Nitrogen unloaded from a small a Dewar Flask to a bucket in a laboratory.
Dewar Flask
Fig: A 25 l liquid nitrogen laboratory Dewar flask.
Inner wall linings are silvered to reduce heat leakage.
Flexible Sensing Probe
Probe is made of series of polyimide layers of thickness 0.0254 mm.
Rakes made of stainless steel tubing, wire, and phenolic insulators weigh (6.70 g/cm).
Internal Structure of Cryo-Tracker
Silicon diode sensors incorporated with the probe.
Conductor Traces which constitute the rake of the temp- element

Installed Cryo-Tracker Probe
Cryo-Tracker probe 60 ft. long.
2.5 cm wide.
containing 26 silicon diode sensors.
It’s weight is less than 0.59 kg.
Stratification of Sub-cooled Propellants
The heat leak causes the propellant to warm and stratify due to natural buoyancy forces.
Cryo-Tracker
Initially designed for incorporating in the propellant vessels of reusable launch vehicles.
Purpose of Cryo-Tracker
For knowing the amount of propellant loaded in.
For knowing the liquid & ullage temperature.
For knowing liquid level.
Mass Gauging Method
The entire liquid and ullage temperature profile is first obtained.
Tank pressure can then be used to calculate a liquid density profile.
Liquid density profile is integrated over the known tank volume.
Dual-Purpose Probe.
Temperature measured using silicon diode sensors.
Liquid level detection accuracy is a function of the sensor spacing.
For 12 inch sensor spacing, the overall liquid level accuracy is ± 6 inches.
Performance
Consistent thermal response can be
seen between the sensing elements in
a dual-element probe when it’s thermal-cycled in liquid nitrogen.
Hot-Fire Test (anomaly condition)
The probe is also capable of measuring transient fluid temperature changes.
Figure : Tracking the rapid change in liquid oxygen temperature when warm gases injected into the tank mixed the contents.
Advantages of Cryo-Tracker
Operating Costs
Accuracy
Reliability
Safety
Efficiency
Scalability
Flexibility
Commercial Applications
Cryogenic storage and transport tanks
Home oxygen vessels
Medevac helicopter and military field hospital oxygen-generating systems
Automobiles running on liquid hydrogen or liqufied natural gas

Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Tagged Pages: croyo tracker mass temperature gauging sensor seminar report in detail,
Popular Searches: telephone number tracker, network tracker, customer tracker, tracker by gary paulsen, mobile name tracker, research papers on cryo car, cryo tracker full report,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  NanoTechnology (Download Full Seminar Report) Computer Science Clay 39 57,103 16-08-2018, 01:41 PM
Last Post: pradeepkumar.M
  magnetic refrigeration full report project report tiger 46 45,807 20-06-2018, 11:43 PM
Last Post: Guest
  TQM Total quality management full report project report tiger 5 14,146 18-09-2016, 08:41 PM
Last Post: velraj
  thermoacoustic refrigeration full report project report tiger 12 19,946 06-03-2015, 06:28 PM
Last Post: Guest
  the gurney flap full report project report tiger 1 3,608 04-12-2014, 02:02 PM
Last Post: pricemuzDet
  exhaust gas recirculation full report project report tiger 8 10,909 05-11-2014, 09:06 PM
Last Post: jaseela123d
  IMPROVEMENT OF THERMAL EFFICIENCY BY RECOVERY OF HEAT FROM IC ENGINE EXHAUST full rep project report tiger 7 8,578 18-10-2014, 10:35 PM
Last Post: jaseela123d
  reverse engineering full report project report tiger 3 6,511 11-10-2014, 10:49 PM
Last Post: Guest
  sensotronic brake control full report computer science technology 13 24,142 07-10-2014, 10:01 PM
Last Post: seminar report asees
  anti lock braking system full report project report tiger 6 8,586 23-09-2014, 07:25 PM
Last Post: seminar report asees

Forum Jump: