underground cable fault distance locator pdf
#1

please give me information about the project
'underground cable fault distance locater' .
circuit diagram,detailed information about every component used in project.
Reply
#2

While a fault occurs for some reason, at that time the repair process related to that particular cable is difficult due to not knowing the exact location of the cable fault. The proposed system is to find the exact location of the fault.


The  uses the standard concept of Ohms law, ie when a low voltage is applied at the end of the feeder through a series resistor (cable lines), then the current will vary depending on the location of the fault in the wire.

In case of a short-circuit (Line to Earth), the voltage across the series resistors changes accordingly, which is then fed to an ADC to develop precise digital data that the programmed microcontroller of the 8051 family would display in kilometers.

The project is assembled with a set of resistors that represent the length of the cable in KM and the creation of failures is done by means of a set of switches in each known KM to verify the accuracy of the same. The fault that occurs at a certain distance and the respective phase is displayed on an LCD screen connected to the microcontroller.
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Popular Searches: ieee papers on underground cable fault distance locater pdf download, future scope of underground cable fault distance locator pdf, underground bandhara pdf, underground cable fault distance locator pdf, automatic fault locator on power system pdf, underground cable fauit distance locatar project pdf, future scope of underground cable fault detector pdf,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  how to calculate distance in heed protocol by using matlab 1 1,887 15-06-2018, 03:54 PM
Last Post: Guest
  disadvantages of underground cable fault distance locator 1 1,304 12-04-2017, 03:52 PM
Last Post: jaseela123d
  distance measurement using infrared sensor with adc0804 8051 microcontroller at89c51 1 2,115 12-04-2017, 12:57 PM
Last Post: jaseela123d
  ppt for microcontroller based ultrasonic distance meter 1 916 05-04-2017, 05:00 PM
Last Post: jaseela123d
  fault detection of optical fibre using 8051 1 780 04-04-2017, 05:01 PM
Last Post: jaseela123d
  ppt on fault prediction in object oriented systems 1 646 31-03-2017, 02:28 PM
Last Post: jaseela123d
  distance limit of sniffer for detecting lost mobiles 1 733 31-03-2017, 01:58 PM
Last Post: jaseela123d
  ultrasonic distance meter free pdf file 1 777 28-03-2017, 10:40 AM
Last Post: jaseela123d
  schematics for cable fault locator using microcontroller 1 643 24-03-2017, 03:24 PM
Last Post: jaseela123d
  schematics for cable fault locator using microcontroller 1 593 24-03-2017, 03:23 PM
Last Post: jaseela123d

Forum Jump: