The design standards required for an auditorium.
Reply
#2

OVERVIEW
The Auditorium space types are areas for large meetings, presentations, and performances. Auditorium space type facilities may include assembly halls, exhibit halls, auditoriums, and theaters. Auditorium space types do not include such features as sound reinforcement systems, audiovisual systems and projection screens, food service facilities, proscenium stages with heights greater than 50'- 0" or fly gallery, orchestra pits, revolving or hydraulic stage platforms, flying balconies, movable seating, or billboard systems.

SPACE ATTRIBUTES
Auditorium spaces are designed to accommodate large audiences. As such, they tend to have wide spans and are multiple-stories high in order to accommodate seating, sightline, and acoustical requirements. Raised stage/dais floors and special lighting equipment are often required as well. Typical features of Auditorium space types include the list of applicable design objectives elements as outlined below. For a complete list and definitions of the design objectives within the context of whole building design, click on the titles below.

Functional / Operational
Sloped Floors: Sloped floors, with level terraces for each row of seating, help provide the proper sightlines from the audience to the stage. Note that the bottom and intermediate rows should be directly accessible from entry levels to allow for Americans with Disabilities Act Accessibility Guidelines for Buildings and Facilities (ADAAG) compliant accessible seating positions. See also WBDG Accessible.
Fixed Seats: Typically, fixed seats with tilting upholstered seat and back, integral arm and tablet arm are provided with articulated back for maximum occupant passage space between rows. The seats may be fully upholstered or wood contoured outer back and seat shells with wood armrests with tablet arm option and aisle light option at row ends. Seat number/row letters should be Americans with Disabilities Act (ADA) compliant. Wheelchair access option-removable seats in sections of two and accessible end chairs for mobility limited occupants should be provided. See also WBDG Accessible.
Special Lighting: Dramatic lighting systems include front lighting, foot lighting, spot lights, follow spot lights, beam lights, and flood lights, and a projection room/booth with manual and programmable lighting controls, and space for the spot light operator space. Lighting systems should be flexible to accommodate various performance venues (e.g., lectures, plays, musical performances, etc.) in the Auditorium.
Occupancy: Occupancy Group Classification is Assembly A1 or A3 as per IBC, with sprinkler protected construction, and GSA Acoustical Class A space requiring special acoustical design. See also WBDG Secure / Safe—Plan for Fire Protection.
Productive
Special Acoustical Design: Quality acoustical characteristics are important in Auditorium spaces so that performances and presentations can be clearly heard and understood. For performance spaces and general presentation spaces, recommended noise criteria (NC) rating ranges from NC-20 to NC-30; recommended sound transmission class (STC) rating ranges from STC 40 to STC 50. Strategies to achieve the recommended NC and STC ranges include, for example: Type II vinyl wall covering and fabric covered acoustical wall panels for the interior wall finish in the auditorium; Type II vinyl wall covering for the stage area; Type II vinyl wall coverings for 1/3 of the front of the orchestra (audience) sidewalls and fabric covered acoustical panels for 2/3 of the back of the orchestra (audience) sidewalls; fabric covered acoustical panels for rear walls; and a plaster and plywood combination—because of their reverberation characteristics—for the ceiling. For more information, see WBDG Productive—Provide Comfortable Environments.
Sustainable
Increased Cooling Capacity: Heating, ventilating, and air-conditioning (HVAC) systems for Auditorium spaces are sized and zoned to accommodate varying internal loads, which are a function of audience sizes, performance lighting loads, and projection equipment. Particularly, air handling units (AHUs) with increased cooling capacity should be zoned separately for the auditorium, lobby, projection spaces, stage areas, and audience seating areas. Also, the Auditorium typically has a separate AHU constant volume with modulated temperature control for ventilation. For more information, see WBDG High-Performance HVAC.
Raised Floor: The recommended system for distribution of HVAC in auditorium spaces is ducted supply through floor vents with ducted ceiling return air vents in auditorium and lobby. In other spaces, ducted ceiling supply with return air ceiling plenum is recommended. Note that there should be transfer ducts at all acoustically rated partitions.
Secure / Safe
Fire and Life Safety: Proper notification systems, lighting, and signage are required to facilitate safe and speedy evacuations during an emergency in the Auditorium spaces. Step lights recessed into floor risers at each seating tier and wall mounted low light level sconce lights along side walls are typical. Sprinklers should be provided per code and under stage platforms to suppress fires. See also WBDG Secure / Safe—Ensure Occupant Safety and Health and Secure / Safe—Plan for Fire Protection.
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Popular Searches: accessible, architectural design of auditorium ppt, case study of auditorium design ppt, ieee standards for software design document, stc 88 4d, auditorium design standards pdf india, synopsis for project on auditorium design,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  industrial self supporting chimney design calculation 0 8,264 11-02-2021, 05:11 PM
Last Post:
  computer aided design vijayaraghavan book free download 2 10,015 27-11-2018, 04:49 PM
Last Post:
  vlsi design by kvkk prasad pdf 0 858 24-10-2018, 05:31 AM
Last Post: Guest
Information vlsi design by kvkk prasad pdf 0 871 23-10-2018, 10:27 PM
Last Post: Guest
  go kart design report in ieee format 0 5,968 06-10-2018, 04:21 PM
Last Post: Guest
  free download design of rectangular water tanks in xls 0 983 30-09-2018, 12:01 PM
Last Post: Guest
  computer aided design vijayaraghavan book free download 0 1,042 23-08-2018, 11:17 AM
Last Post: Guest
Rainbow design fabrication of hydraulic sheet bending machine wikipedia 3 1,174 15-08-2018, 06:10 PM
Last Post: Guest
  computer aided design vijayaraghavan book free download 0 661 26-07-2018, 08:04 PM
Last Post: Guest
  design of sarda type fall ppt 0 463 26-07-2018, 06:43 PM
Last Post: Guest

Forum Jump: