advantages and disadvantages of fire alarm circuit using LDR
#1

Advantages and disadvantages of  fire alarm circuit using LDR
Reply
#2
When there is no smoke, the focus light will fall directly on the LDR. The LDR resistance will be low and therefore the voltage across it (below 0.6 V). The transistor will be off and nothing happens. When there is enough smoke to hide the light falling on LDR, the LDR resistance increases and also increases the voltage across it. Now the transistor will turn ON. This gives power to the IC1 and emits 5V. This activates the UM66 (IC2) IC tone generator for playing music. This music will be amplified by IC3 (TDA 2002) to drive the speaker. The resistor R6 is intended to protect the transistor when R4 is rotated towards low resistance values. The resistor R2 and R1 form a feedback network for the TDA2002 and C1 couples the feedback signal from the junction of R1 and R2 to the inverting input of the same IC. Diode D1 and D2 in combination falls 1.4 V to give nominal voltage (3.5V) to UM66. UM66 can not withstand more than 4V.

Circuit diagram with parts list:

[Image: fire-alarm-circuit1.jpg]
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Popular Searches: how ldr works in heartbeat sensord disadvantages, disadvantages of using an ldr, advantages of ldr, project report on fire alarm using ldr, automatic street liggt system circuit advantages and disadvantages, advantages and disadvantages of a light alarm, ldr alarm using transistor 558 and 548,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  Over Speed Alarm Indicators of Electrical Motor with Digital RPM Indicator 0 295 25-07-2023, 05:33 AM
Last Post:
  well-spring some homemade barbecue backchat and moistureless rubs and the actuality 0 1,058 10-09-2019, 05:48 PM
Last Post:
  agent some homemade barbecue cheek and prosaic rubs and suit 0 972 10-09-2019, 07:04 AM
Last Post:
  pass some homemade barbecue coolness and arid rubs and module 0 932 09-09-2019, 06:35 PM
Last Post:
  Earthquake detection alert alarm for people security ppt 0 886 06-01-2019, 09:29 AM
Last Post:
  Earthquake detection alert alarm for people security 0 806 06-01-2019, 09:25 AM
Last Post:
Wink disadvantages of plastic in malayalam essay 2 2,470 29-12-2018, 06:07 AM
Last Post:
  traffic alert system circuit for blind tums 0 677 04-11-2018, 02:42 PM
Last Post: Guest
  fire alarm project for class xii pdf 0 1,206 31-10-2018, 08:37 PM
Last Post: Guest
  disadvantages of smart dustbin 0 660 27-10-2018, 03:47 PM
Last Post: Guest

Forum Jump: