Adaptive Feedforward and Feedback Control Schemes for Sliding Mode Controlled Power
#1

Abstract”
A major disadvantage of applying sliding mode control to dc/dc converters is that the steady-state switching frequency is affected by line and load variations. This is undesirable as it complicates the design of the input and output filters. To reduce switching frequency deviation in the events of line and load variations, an adaptive feedforward control scheme that varies the hysteresis band according to the change of line input voltage and an adaptive feedback control scheme that varies the control parameter (i.e., sliding coefficient) according to the change of the output load are proposed. This paper presents a thorough investigation into the problem and the effectiveness of the proposed solutions. In addition, methods of implementing the proposed adaptive control strategies are discussed. Experimental results confirm that the adaptive control schemes are capable of reducing the switching frequency variations caused by both line and load variations.

Siew-Chong Tan, Y. M. Lai, Chi K. Tse, and
Martin K. H. Cheung
read full report
http://jpe.or.kr/On_line/admin/paper/fil...E-0973.pdf
http://citeseerx.ist.psu.edu/viewdoc/dow...1&type=pdf
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Popular Searches: tv switch mode power supply diagrams, adaptive feedforward and feedback control schemes for sliding mode controlled power converters pdf, onthejob training feedback questionnaire, what devices are controlled through windows power schemes, special schemes for technical entreprenenurs, seminar abstract and report on i mode, sliding mode control pptting interview questions in bsnl,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  Adaptive piezoelectric energy harvesting circuit for wireless remote power supply electronics seminars 3 4,555 18-02-2016, 02:18 PM
Last Post: seminar report asees
  DC MOTOR CONTROL USING CHOPPER seminar class 3 5,727 25-11-2015, 02:00 PM
Last Post: seminar report asees
  Biomass Fuelled Power Plant computer science crazy 6 5,869 08-05-2015, 02:21 PM
Last Post: seminar report asees
  seminar on power grid 2 8,781 24-08-2014, 12:42 AM
Last Post: Guest
  artificial intelligence techniques in power systems full report computer science technology 3 5,694 08-08-2014, 10:39 PM
Last Post: seminar report asees
  thermoelectric power generation full report project report tiger 8 8,178 07-03-2014, 07:43 PM
Last Post: Guest
  Space Time Adaptive Processing computer science crazy 4 5,124 04-03-2014, 07:03 PM
Last Post: Guest
  Cellular through remote control switch computer science crazy 4 4,691 22-07-2013, 12:10 PM
Last Post: computer topic
  Voltage Stability Improvement using Static Var Compensator in Power Systems project report tiger 4 13,388 12-07-2013, 11:29 AM
Last Post: computer topic
  GEOTHERMAL POWER GENERATING TECHNOLOGY project topics 11 9,498 25-06-2013, 10:00 AM
Last Post: computer topic

Forum Jump: