A Novel MEMS Respiratory Flow Sensor
#1

Abstract
A novel CMOS-process-compatible MEMSsensor formonitoring respiration is presented. This resistive flow sensor wasmanufactured by the TSMC 0.35 m CMOS/MEMS mixed-signal2P4M Polycide process. The sensor was demonstrated to be sensitiveenough to detect the respiratory flow rate, and the relationshipbetween flow rate and sensed voltage is quite linear. If one canintegrate the sensor with its sensing circuit into a single chip, thecost of a pneumotach system can be greatly reduced. Moreover, theproposed sensor is useful in both invasive and noninvasive applications.
Index Terms—CMOS/MEMS, flow sensor, respiratorymonitoring.
I. INTRODUCTION
RESPIRATORY activity is commonly monitored clinicallyto prevent sudden infant death syndrome, or torecord a patient’s physiological status for sleep studies andsports training [1], [2]. Various sensors and sensing methodshave been developed to measure respiratory rate and/or lungcapacity, including the monitoring or measurement of transthoracicimpedance, blood O CO concentration, and breathingairflow [1]–[4]. Among them, breathing airflow measurement isthe most direct method, since it measures airflow directly, ratherthan estimating it by measuring another parameter (O COconcentration or transthoracic impedance).Breathing airflow is typically detected by sensing pressure ortemperature, and the adopted sensors may be resistive, thermoelectric,pyroelectrical, or piezoelectric. In the present work, aresistive, CMOS-process-compatible flow sensor is proposed.Advances in CMOS manufacturing process techniques make itpossible to integrate the flow sensor, sensing and postprocessingcircuits into a single chip, greatly reducing the cost of a pneumotachsystem. According to the experimental data, the proposedsensor is sufficiently sensitive to detect respiratory rate.
II. SENSOR DESIGN
A. Principle of the Sensor

The flow velocity of exhaled breath is denoted . When ithits the surface of the sensor, the particles lose their momentum which is then converted to a force, , exerted on the sensorsurface(1)where is the total mass of the air particles that hit the sensorper unit time, . is given by(2)where is the density of the air particles, and is the surfacearea of the sensor. Combining (1) with (2), the exerted force isgiven by(3)The pressure applied on the sensor surface, , is(4)The sensor is deformed by the applied pressure. If the sensor isdesigned such that the deformation elongates its length and/ordecreases its cross-sectional area, then the change in the sensorresistance is proportional to the applied pressure, according tothe Ohm’s law [5](5a)(5b)where is the original sensor resistance; is its original length;is its original cross-sectional area; , , and are theirchanges due to the applied pressure, respectively. From (4) and(5b), the change in the sensor resistance is proportional to theapplied pressure and, thus, the velocity of the airflow. However,the air temperature, humidity and density changes in the inhalationand exhalation phases are not considered here.
B. Structure of the Sensor
The sensor, which is actually a miniaturized cantilever, wasmanufactured by the TSMC 0.35- m CMOS/MEMS 2P4Mpolycide mixed-signal process [6]. Fig. 1 shows the physicalstructure of the cantilever with its thickness exaggerated. Theresistance of the sensor was dominated by the ploy 2 layer, andthe underneath well was emptied. Each cantilever was 500 mlong, 30 wide, and 7 m thick. The ploy 2 was laid as a Ushape to increase the available cantilever resistance in a limitedarea.

Download full report
http://ieeexplore.ieeeiel5/7361/5350892/...er=5350894
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Popular Searches: mems 3d sensor ppt, respiratory temperature monitor in icu seminar topics abstract, respiratory system, online college for respiratory therapy, wireless mems sensor network seminar, ceu seminars respiratory, santa fe college respiratory therapy,

[-]
Quick Reply
Message
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  Privacy- and Integrity-Preserving Range Queries in Sensor Networks 1 881 15-02-2017, 04:10 PM
Last Post: jaseela123d
  Protecting Location Privacy in Sensor Networks Against a Global Eavesdropper 1 816 15-02-2017, 11:01 AM
Last Post: jaseela123d
  Protecting Location Privacy in Sensor Networks Against a Global Eavesdropper 1 786 15-02-2017, 11:00 AM
Last Post: jaseela123d
  Fast Data Collection in Tree-Based Wireless Sensor Networks Projects9 9 4,020 12-03-2014, 06:30 PM
Last Post: computer topic
  A Novel Framework for Semantic Annotation and Personalized Retrieval of Sports Video electronics seminars 4 3,058 23-03-2013, 07:40 PM
Last Post: [email protected]
  DISTRIBUTED MOBILITY MANAGEMENT FOR TARGET TACKING IN MOBILE SENSOR NETWORKS computer science technology 4 3,951 22-02-2013, 03:05 PM
Last Post: seminar details
  The Wireless Sensor Network for Home-Care System Using ZigBee smart paper boy 1 1,985 31-01-2013, 11:34 AM
Last Post: seminar details
  WISENET (Wireless Sensor Network) ppt. seminar surveyer 9 12,609 08-12-2012, 02:49 PM
Last Post: seminar details
  A TABU SEARCH ALGORITHM FOR CLUSTER BUILDING IN WIRELESS SENSOR NETWORKS- MOBILE COMP electronics seminars 1 2,080 01-12-2012, 12:06 PM
Last Post: seminar details
  A Tabu Search Algorithm for Cluster Building in Wireless Sensor Networks Electrical Fan 13 8,697 01-12-2012, 12:05 PM
Last Post: seminar details

Forum Jump: